Literature DB >> 18968980

Determination of paraquat in human blood plasma using reversed-phase ion-pair high-performance liquid chromatography with direct sample injection.

M R Brunetto1, A R Morales, M Gallignani, J L Burguera, M Burguera.   

Abstract

This report describes the determination of paraquat (PQ) in human blood plasma samples by a direct-injection reversed-phase ion-pair chromatographic method. Blood plasma filtrate was injected directly into the LiChrospher(R) RP-18 alkyl-diol silica (ADS) precolumn integrated in a column switching system using a mixture of 3% 2-propanol and 10 mM sodium octane sulfonate (SOS) in a 0.05 M phosphate buffer (pH 2.8). After washing with this phase, the ADS precolumn was back-flushed with the analytical mobile phase consisting of 40% of methanol and 10 mM SOS in a 0.05 M phosphate buffer (pH 2.8) at a flow rate of 1.0 ml min(-1), in order to carry the analyte to a conventional reversed-phase analytical column, where the separation of PQ was achieved and finally detected by UV at 258 nm. The recoveries of PQ from human blood plasma samples ranged between 95.0 and 99.5% at nine different concentrations (from 0.05 to 3.00 microg of PQ ml(-1)) with coefficients of variation <2.5% (n=3). The precision expressed as relative standard deviation was below 3.5% for between-day and below 4.3% for within-day measurements (n=5). The detection limit (signal-to-noise ratio, S/N>3) was 0.005 microg ml(-1) with an injection volume of 200 microl. The proposed method is promising for the identification and quantification of PQ at low concentration levels and is suitable for its analysis in human blood plasma samples from intentional or accidental poisonings cases with a sample throughput of 5 samples per hour.

Entities:  

Year:  2003        PMID: 18968980     DOI: 10.1016/S0039-9140(02)00645-8

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Clearance rate and BP-ANN model in paraquat poisoned patients treated with hemoperfusion.

Authors:  Lufeng Hu; Guangliang Hong; Jianshe Ma; Xianqin Wang; Guanyang Lin; Xiuhua Zhang; Zhongqiu Lu
Journal:  Biomed Res Int       Date:  2015-01-28       Impact factor: 3.411

2.  Supramolecular Solvent-Based Liquid Phase Microextraction Combined with Ion-Pairing Reversed-Phase HPLC for the Determination of Quats in Vegetable Samples.

Authors:  Sophon Hem; Netsirin Gissawong; Supalax Srijaranai; Suthasinee Boonchiangma
Journal:  Toxics       Date:  2019-11-26

3.  Electrochemical determination of paraquat in citric fruit based on electrodeposition of silver particles onto carbon paste electrode.

Authors:  Abdelfettah Farahi; Mounia Achak; Laila El Gaini; Moulay Abderrahim El Mhammedi; Mina Bakasse
Journal:  J Food Drug Anal       Date:  2015-05-19       Impact factor: 6.157

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.