Literature DB >> 18968857

Simple flow injection system for colorimetric determination of iodate in iodized salt.

N Choengchan1, K Uraisin, K Choden, W Veerasai, Kate Grudpan, D Nacapricha.   

Abstract

This work presents a flow injection (FI) system that was developed for determination of iodate. The system utilizes the oxidation of iodide by the analyte to iodine, which subsequently forms tri-iodide. In the presence of starch, the blue I(3)(-)-starch complex is developed within the sample zone and can be colorimetrically detected at 590 nm. Optimization was carried out to make the system suitable for quantitating iodate added to table salts. To prevent accumulation of the blue complex residue on walls of tubing and the flow cell, a port was placed in the system for injection of 10(-3) M thiosulfate plug (100 mul). An injection of this cleaning solution after each sample injection is recommended to avoid positive baseline shift. By means of the paired t-test, the amounts of iodine (mg I kg(-1)) were statistically compared with the results determined by titration and by iodide ion selective electrode. No significant disagreement at 95% confidence was observed. The proposed system is very simple, uses common chemicals and provides rapid analysis (65 injections per h) with high precision (R.S.D.=0.66%, n=10). A detection limit of 2 mg I kg(-1) salt can be achieved.

Entities:  

Year:  2002        PMID: 18968857     DOI: 10.1016/s0039-9140(02)00438-1

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A convenient and sensitive colorimetric iodide assay based on directly inducing morphological transformation of gold nanostars.

Authors:  Rongju Zhou; Xiaohui Huang; Qingxiao An; Weizhen Xu; Yi Liu; Dong Xu; Qinlu Lin; Suyan Wang; Jianglin Zhang
Journal:  J Food Drug Anal       Date:  2021-03-15       Impact factor: 6.157

2.  Determination of iodate in food, environmental, and biological samples after solid-phase extraction with Ni-Al-Zr ternary layered double hydroxide as a nanosorbent.

Authors:  Hossein Abdolmohammad-Zadeh; Keyvan Tavarid; Zeynab Talleb
Journal:  ScientificWorldJournal       Date:  2012-04-24

3.  Chip-Based Spectrofluorimetric Determination of Iodine in a Multi-Syringe Flow Platform with and without In-Line Digestion-Application to Salt, Pharmaceuticals, and Algae Samples.

Authors:  Joana L A Miranda; Raquel B R Mesquita; Edwin Palacio; José M Estela; Víctor Cerdà; António O S S Rangel
Journal:  Molecules       Date:  2022-02-16       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.