Literature DB >> 18968856

Determination of rare earth elements in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry.

Shizuko Hirata1, Tasuku Kajiya, Masato Aihara, Kazuto Honda, Osamu Shikino.   

Abstract

A home made column of commercially available iminodiacetate resin, Muromac A-1 (50-100 mesh) was used to concentrate rare earth elements (REEs) (15 elements: Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) in seawater. An automated low pressure flow analysis method with on-line column preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) is described for the determination of REEs in seawater. Sample solutions (adjusted to pH of 3.0) passed through the column. After washing the column with water, the adsorbed elements were subsequently eluted into the plasma with 0.7 M nitric acid. Calibration curves were accomplished by means of purified artificial seawater with a sample loading time of 120 s. Detection limits (DLs) of the on-line column preconcentration/ICP-MS by eight replicate operations were between 0.040 and 0.251 pg ml(-1) for REEs in the artificial seawater. The precision was less than 8.9% for REEs and one sample can be processed in 7 min using a 7 ml of sample. The proposed method was applied to determine REEs in coastal seawater of Hiroshima Bay, Japan.

Entities:  

Year:  2002        PMID: 18968856     DOI: 10.1016/s0039-9140(02)00418-6

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Flow injection on-line solid phase extraction coupled with inductively coupled plasma mass spectrometry for determination of (ultra)trace rare earth elements in environmental materials using maleic acid grafted polytetrafluoroethylene fibers as sorbent.

Authors:  Zhao-Hui Wang; Xiu-Ping Yan; Zhi-Peng Wang; Zheng-Pu Zhang; Li-Wen Liu
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-30       Impact factor: 3.109

2.  Solid phase extraction of rare earth elements in seawater and estuarine water with 4-(2-thiazolylazo) resorcinol immobilized Chromosorb 106 for determination by inductively coupled plasma mass spectrometry.

Authors:  Fahmida Zereen; Vedat Yilmaz; Zikri Arslan
Journal:  Microchem J       Date:  2013-09-01       Impact factor: 4.821

3.  Fast Determination of Yttrium and Rare Earth Elements in Seawater by Inductively Coupled Plasma-Mass Spectrometry after Online Flow Injection Pretreatment.

Authors:  Zuhao Zhu; Airong Zheng
Journal:  Molecules       Date:  2018-02-23       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.