Literature DB >> 18968824

Square-wave cathodic stripping voltammetric analysis of RDX using mercury-film plated glassy carbon electrode.

Suw-Young Ly1, Duck-Ho Kim, Myung-Hoon Kim.   

Abstract

A mercury film (MF) is prepared by an electrochemical deposition on a glassy carbon electrode (GCE), and employed for an analysis of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) using square-wave stripping voltammetry (SWSV). RDX was deposited at -0.15 V (vs. Ag/AgCl) for 120 s, then reduced at -0.7 V on the MF coated GCE(MFGCE). Optimal experimental conditions were searched and reported for the analysis. Two linear concentration ranges were observed: one in a lower RDX concentration range of 0.2-10 mg l(-1) and the other in a higher RDX concentration range of 10.0-100.0 mg l(-1) with a 120 s of pre-concentration time. At RDX concentrations of 2 and 8 mg l(-1), the relative standard deviations in measured concentrations (n=16) were 9.79 and 0.49%, respectively. The detection limit found to be 0.12 mg l(-1) with the 120 s accumulation time. The method was applied to determine RDX in several soil samples that yielded a relative error of 1% in the concentrations.

Entities:  

Year:  2002        PMID: 18968824     DOI: 10.1016/s0039-9140(02)00442-3

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Voltammetric bioassay of caffeine using sensor implant.

Authors:  Suw Young Ly; Chang Hyun Lee; Young Sam Jung
Journal:  Neuromolecular Med       Date:  2009-01-01       Impact factor: 3.843

2.  Voltammetric Assay of Mercury Ion in Fish Kidneys.

Authors:  Suw Young Ly
Journal:  Toxicol Res       Date:  2008-03-01

3.  Analysis of Lead Ions in a Waste Solution Using Infrared Photo-Diode Electrode.

Authors:  Suw Young Ly; Hyun Kuy Lee; Kyu Ju Kwak; Jun Seok Ko; Jeong Jae Lee; Jin Hee Cho; Ki Hong Kim; Min Seok Kim; So Jung Lee
Journal:  Toxicol Res       Date:  2008-09-01
  3 in total