| Literature DB >> 18968474 |
Abstract
In this paper, a new voltammetric method for the determination of phenol is described. In pH 8.00 phosphate buffer and in the presence of long-chain cationic surfactant-cetyltrimethylammonium bromide-phenol has a very sensitive oxidation peak at 0.47 V (vs. SCE) on the Nafion-modified glassy carbon electrode (GCE). The experimental parameters, such as supporting electrolyte and pH values, amounts of Nafion, varieties and concentration of surfactants, accumulation potential and time, as well as scan rate were optimized. The peak current is linear with the concentration of phenol in the range from 8x10(-9) to 1x10(-5) M, and the detection limit is 1x10(-9) M after being accumulated at -0.50 V (vs. SCE) for 3 min. Trace levels of phenol in water samples were determined by using this voltammetric method, the average recovery was calculated to be 99.56%.Entities:
Year: 2001 PMID: 18968474 DOI: 10.1016/s0039-9140(01)00531-8
Source DB: PubMed Journal: Talanta ISSN: 0039-9140 Impact factor: 6.057