Literature DB >> 18968235

Electrothermal atomic absorption spectrometric determination of cobalt, copper, lead and nickel traces in aragonite following flotation and extraction separation.

D Zendelovska1, G Pavlovska, K Cundeva, T Stafilov.   

Abstract

A method of determination of Co, Cu, Pb and Ni in nanogram quantities from aragonite is presented. Flotation and extraction of Co, Cu, Pb and Ni is suggested as methods for elimination matrix interferences of calcium. The method of flotation is performed by iron(III) hexamethylenedithiocarbamate, Fe(HMDTC)(3), as a colloid precipitate collector. The liquid-liquid extraction of Co, Cu, Pb and Ni is carried out by sodium diethyldithiocarbamate, NaDDTC, as complexing reagent into methylisobutyl ketone, MIBK. The electrothermal atomic absorption spectrometry (ETAAS) is used for determination of analytes. The detection limits of ETAAS followed by flotation are: 7.8 ng.g(-1) for Co, 17.1 ng.g(-1) for Cu, 7.2 ng.g(-1) for Pb and 9.0 mug.g(-1) for Ni. The detection limits of ETAAS followed by extraction are found to be: 12.0 ng.g(-1) for Co, 51.0 ng.g(-1) for Cu, 24.0 ng.g(-1) for Pb and 21.0 ng.g(-1) for Ni.

Entities:  

Year:  2001        PMID: 18968235     DOI: 10.1016/s0039-9140(00)00645-7

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  The use of rapidly synergistic cloud point extraction for the separation and preconcentration of trace amounts of Ni (II) ions from food and water samples coupling with flame atomic absorption spectrometry determination.

Authors:  Reyhaneh Rahnama; Marzieh Najafi
Journal:  Environ Monit Assess       Date:  2016-02-09       Impact factor: 2.513

2.  Determination of Trace Amounts of Lead Using the Flotation-spectrophotometric method.

Authors:  Sabah Shiri; Ali Delpisheh; Ali Haeri; Abdolhossein Poornajaf; Babak Golzadeh; Sina Shiri
Journal:  Anal Chem Insights       Date:  2010-12-20

3.  Single-channel flow injection spectrophotometric determination of nickel using furildioxime in micellar solution.

Authors:  Najma Memon; Saima Memon; Amber R Solangi; Rubina Soomro; Rabel Soomro
Journal:  ScientificWorldJournal       Date:  2012-05-01

4.  Naphthyridine derived colorimetric and fluorescent turn off sensors for Ni2+ in aqueous media.

Authors:  Abida Ashraf; Muhammad Islam; Muhammad Khalid; Anthony P Davis; Muhammad Tayyeb Ahsan; Muhammad Yaqub; Asad Syed; Abdallah M Elgorban; Ali H Bahkali; Zahid Shafiq
Journal:  Sci Rep       Date:  2021-09-28       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.