Literature DB >> 18968114

Novel mercury (II) ion-selective polymeric membrane sensor based on ethyl-2-benzoyl-2-phenylcarbamoyl acetate.

S S Hassan1, M B Saleh, A A Abdel Gaber, R A Mekheimer, N A Abdel Kream.   

Abstract

Mercury (II) ion-selective PVC membrane sensor based on ethyl-2-benzoyl-2-phenylcarbamoyl acetate (EBPCA) as a novel nitrogen containing sensing material is successfully developed. The sensor exhibits good linear response of 30 mV per decade within the concentration range 10(-6)-10(-3) mol l(-1) Hg(II). The sensor shows good selectivity for mercury (II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. The EBPCA-based sensor is suitable for use with aqueous solutions of pH 2.0-4.5 and exhibits minimal interference by Ag(I) and Fe(III), which are known to interfere with other previously suggested sensors. The nature and composition of the sensing material and its mercury complex are examined using Fourier-transform infrared analysis, elemental analysis and X-ray fluorescence techniques. The proposed sensor is applied as a sensor for the determination of Hg(II) content in some amalgam alloys. The results show good correlation with data obtained by atomic absorption spectrometric method.

Entities:  

Year:  2000        PMID: 18968114     DOI: 10.1016/s0039-9140(00)00445-8

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Aptamer-functionalized porous phospholipid nanoshells for direct measurement of Hg(2+) in urine.

Authors:  Zhen Li; Thusitha P Muhandiramlage; John P Keogh; Henry K Hall; Craig A Aspinwall
Journal:  Anal Bioanal Chem       Date:  2014-10-19       Impact factor: 4.142

Review 2.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

3.  Flow injection analysis of mercury using 4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone as the ionophore of a coated wire electrode.

Authors:  Tara F Tahir; Abdussalam Salhin; Sulaiman Ab Ghani
Journal:  Sensors (Basel)       Date:  2012-11-06       Impact factor: 3.576

4.  A new electrochemical sensor based on task-specific ionic liquids-modified palm shell activated carbon for the determination of mercury in water samples.

Authors:  Ahmed Abu Ismaiel; Mohamed Kheireddine Aroua; Rozita Yusoff
Journal:  Sensors (Basel)       Date:  2014-07-21       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.