Literature DB >> 18968050

Micellar colorimetric determination of iron, cobalt, nickel and copper using 1-nitroso-2-naphthol.

J Yun1, H Choi.   

Abstract

1-Nitroso-2-naphthol, an excellent color-forming chelating agent, combines to Fe(III), Co(II), Ni(II), Cu(II) and so on to form slightly soluble complexes in aqueous solution. To determine these metal ions, a tedious and time consuming separation technique, such as liquid-liquid extraction, has often been performed. However, these metal-1-nitroso-2-naphthol complexes could be determined conveniently by ultraviolet-visible (UV-Vis) spectrophotometry in Tween 80 micellar medium that has polyoxyethylene groups. After conditions such as pH, the amount of 1-nitroso-2-naphthol and the stability were adjusted to their optimum values, the sensitivities of the metal ions in Tween 80 medium and in chloroform were compared. It was shown that the sensitivities of Fe(III) and Co(II) in Tween 80 medium were higher than in chloroform, but that of Cu(II) was lower. The interfering effects among analytes ions, Fe(III), Co(II), Ni(II) and Cu(II) were more serious than by other ions, but the interfering effects could be removed by adjusting pH or adding the masking agents such as NH(3) or oxalate. Detection limits of Fe(III), Co(II), Ni(II), and Cu(II) were 0.024, 0.016, 0.039 and 0.023 mug ml(-1), respectively, and the correlation coefficients of these calibration curves were above 0.996. Recovery yields of the metal ions in the mixed standard solution ranged from 96 to 103%, and their coefficients of variation were low ranging between 0.94 and 1.75%. Cu(II) in brass sample and the amount of Fe(III) in steel sample were also determined. This proposed technique is simple, convenient and speedy.

Entities:  

Year:  2000        PMID: 18968050     DOI: 10.1016/s0039-9140(00)00441-0

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Metal ions guided self-assembly of therapeutic proteins for controllable release: from random to ordered aggregation.

Authors:  Kai Shi; Fude Cui; Hongshu Bi; Yanbo Jiang; Hang Shi; Tao Song
Journal:  Pharm Res       Date:  2012-09-14       Impact factor: 4.200

2.  Potentiometric monitoring of cobalt in beer sample by solid contact ion selective electrode.

Authors:  Hilal Eren; Harun Uzun; Muberra Andac; Seda Bilir
Journal:  J Food Drug Anal       Date:  2014-05-22       Impact factor: 6.157

3.  Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode.

Authors:  Aysenur Birinci; Hilal Eren; Fatih Coldur; Emine Coskun; Muberra Andac
Journal:  J Food Drug Anal       Date:  2016-04-12       Impact factor: 6.157

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.