Literature DB >> 18967910

Determination of rutin and other flavonoids by flow-injection/adsorptive stripping voltammetry using nujol-graphite and diphenylether-graphite paste electrodes.

G J Volikakis1, C E Efstathiou.   

Abstract

The possibility of determination of twelve flavonoids (fisetin, galangin, hesperetin, hesperidin, kaempherol, morin, myricetin, naringin, quercetin, quercitrin, rutin, rhamnetin) using adsorptive stripping voltammetry in a flow injection system is examined. Carbon paste electrodes based on mixtures of nujol-graphite and diphenylether-graphite were used and compared as working electrodes and measurements were made using both 'direct' and 'medium-exchange' procedures. The effect of experimental parameters such as pH, accumulation potential and period, presence of various compounds was examined. Sample size (typically 0.33 ml) is greatly reduced by applying a reciprocating flow of the sample plug through the detector during the preconcentration step. The instrumental sensitivities and lower detection limits were calculated for all flavonoids in all cases. In some cases the differences are so high that determination of certain flavonoids in the presence of excess of others is allowed. Depending on the flavonoid, the electrode type, and the measurement procedure the analytical range and the reproducibility (RSD%) were 10(-5)-10(-8) M and 2.5-10%, respectively. A simple procedure is developed for the electrochemical determination of rutin in a multivitamin preparation.

Entities:  

Year:  2000        PMID: 18967910     DOI: 10.1016/s0039-9140(99)00352-5

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Fast and Sensitive Determination of Bioflavonoids Using a New Analytical System Based on Label-Free Silver Triangular Nanoplates.

Authors:  Aleksei Furletov; Vladimir Apyari; Alexey Garshev; Stanislava Dmitrienko; Yury Zolotov
Journal:  Sensors (Basel)       Date:  2022-01-22       Impact factor: 3.576

2.  A fungus-derived biomass porous carbon-MnO2 nanocomposite-modified electrode for the voltammetric determination of rutin.

Authors:  Hui Cheng; Juan Liu; Yunxiu Sun; Ting Zhou; Qiuyue Yang; Shuyao Zhang; Xiaoping Zhang; Guangjiu Li; Wei Sun
Journal:  RSC Adv       Date:  2020-11-20       Impact factor: 4.036

3.  Efficient extraction of bioactive flavonoids from Celtis sinensis leaves using deep eutectic solvent as green media.

Authors:  Lei Wang; Xianying Fang; Yang Hu; Yiwei Zhang; Zhipeng Qi; Jie Li; Linguo Zhao
Journal:  RSC Adv       Date:  2021-05-18       Impact factor: 3.361

4.  A molecularly imprinted polymer with incorporated graphene oxide for electrochemical determination of quercetin.

Authors:  Si Sun; Mengqi Zhang; Yijun Li; Xiwen He
Journal:  Sensors (Basel)       Date:  2013-04-25       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.