Literature DB >> 18967640

Flow injection potentiometry for enzymatic assay of cholesterol with a tungsten electrode sensor.

M Situmorang1, P W Alexander, D B Hibbert.   

Abstract

Flow injection potentiometry (FIP) for the enzymatic determination of cholesterol is reported. The assay utilises a combination of three enzymes: cholesterol esterase (CE), cholesterol oxidase (COD) and peroxidase (POD). The method is developed by the use of a tungsten wire electrode as a sensor vs. Ag/AgCl in conjunction with a redox mediator ferrocyanide. CE converts esterified cholesterol to free cholesterol, which is then oxidised by COD with hydrogen peroxide as product. Ferrocyanide is converted to ferricyanide by hydrogen peroxide, catalysed by POD, and the tungsten electrode responds to the ratio of ferricyanide to ferrocyanide. Flow injection potentiometry gave well-defined peaks for cholesterol samples with a fast response (30 s). Linear calibration was obtained from 0.05 to 3.0 mM cholesterol, with a slope of 60.2 mV/decade change in cholesterol concentration, and detection limit 0.01 mM cholesterol (S/N=3). Repeatability was 3% (CV). Interferences from commonly found species were shown to be negligible. The sensor cell is simple to construct, and it was free from surface contamination problems over long periods of use. The application of the sensor for the determination of serum cholesterol was demonstrated.

Entities:  

Year:  1999        PMID: 18967640     DOI: 10.1016/s0039-9140(99)00057-0

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  When cholesterol is not cholesterol: a note on the enzymatic determination of its concentration in model systems containing vegetable extracts.

Authors:  Mariona Jové; José C E Serrano; Maria Josep Bellmunt; Anna Cassanyé; Neus Anglès; Jordi Reguant; José R Morelló; Reinald Pamplona; Manuel Portero-Otín
Journal:  Lipids Health Dis       Date:  2010-06-21       Impact factor: 3.876

Review 2.  Catabolism and biotechnological applications of cholesterol degrading bacteria.

Authors:  J L García; I Uhía; B Galán
Journal:  Microb Biotechnol       Date:  2012-02-07       Impact factor: 5.813

3.  Enzymatic Reactions in a Lab-on-Valve System: Cholesterol Evaluations.

Authors:  Jucineide S Barbosa; Marieta L C Passos; M das Graças A Korn; M Lúcia M F S Saraiva
Journal:  Molecules       Date:  2019-08-09       Impact factor: 4.411

4.  Fabricating an Amperometric Cholesterol Biosensor by a Covalent Linkage between Poly(3-thiopheneacetic acid) and Cholesterol Oxidase.

Authors:  Po-Chin Nien; Po-Yen Chen; Kuo-Chuan Ho
Journal:  Sensors (Basel)       Date:  2009-03-13       Impact factor: 3.576

  4 in total