Continuous monitoring for cyanide in waste water with a galvanic hydrogen cyanide sensor using a purge system.

H Hachiya1, S Ito, Y Fushinuki, T Masadome, Y Asano, T Imato.   

Abstract

A continuous monitoring system for cyanide with a galvanic hydrogen cyanide sensor and an aeration pump for purging was developed. Hydrogen cyanide evolved from cyanide solution using a purging pump was measured with the hydrogen cyanide sensor. The system showed good performance in terms of stability and selectivity. A linear calibration curve was obtained in the concentrating range from 0 to 15 mg dm(3) of cyanide ion with a slope of -0.24 microA mg(-1) dm(-3). The lower detection limit was 0.1 mg dm(-3). The 90% response time of the sensor system was within 3.5 min for a 0.5 mg dm(-3) cyanide solution, when the flow rate of the purging air was 1 dm(3) min(-1). The system maintained the initial performance for 6 months in the field test. The developed galvanic sensor system was not subject to interference from sulfide and residual chlorine, compared with a potentiometric sensor system developed previously. The analytical results obtained by the present system were in good agreement with those obtained by the pyridine pyrazolone method. The correlation factor and regression line between both methods were 0.979 and Y=2.30 x 10(-4)+1.12X, respectively. This system was successfully applied for a continuous monitoring of cyanide ion in waste water.

Entities:  

Year:  1999        PMID: 18967542     DOI: 10.1016/s0039-9140(98)00314-2

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A new Dual-Channel Chemosensor Based on Chemodosimeter Approach for Detecting Cyanide in Aqueous Solution: a Combination of Experimental and Theoretical Studies.

Authors:  Jae Jun Lee; Sun Young Lee; Kwon Hee Bok; Cheal Kim
Journal:  J Fluoresc       Date:  2015-08-06       Impact factor: 2.217

2.  Pyrene functionalized oxacalix[4]arene architecture as dual readout sensor for expeditious recognition of cyanide anion.

Authors:  Falak Panjwani; Shuvankar Dey; Anita Kongor; Anshu Kumar; Manthan Panchal; Krunal Modi; Manoj Vora; Ashu Kumar; Vinod Kumar Jain
Journal:  J Fluoresc       Date:  2022-04-19       Impact factor: 2.525

3.  A Novel Thiophene-Based Fluorescent Chemosensor for the Detection of Zn2+ and CN-: Imaging Applications in Live Cells and Zebrafish.

Authors:  Min Seon Kim; Dongju Yun; Ju Byeong Chae; Haeri So; Hyojin Lee; Ki-Tae Kim; Mingeun Kim; Mi Hee Lim; Cheal Kim
Journal:  Sensors (Basel)       Date:  2019-12-11       Impact factor: 3.576