Literature DB >> 18967415

Electrochemical behaviour of gold, silver, platinum and palladium on the glassy carbon electrode modified by chitosan and its application.

X Ye1, Q Yang, Y Wang, N Li.   

Abstract

The chitosan-modified glassy carbon electrode can be used as a working electrode for the determination of precious metal elements: Au, Ag, Pt, Pd. In low pH medium, the complex anions of these precious elements combine with the protonated group NH(3)(+) in the chitosan molecule in the form of an ion-association complex. These metal ions were selectively enriched and we got sensitive anodic stripping current. These elements content in ore, welding material have been determined by this method. The results were consistent with those from standard sample and ICP atomic emission spectrometry method. The possible mechanism of electrochemical reaction has been proposed by the study of CV, UV and FT-Raman spectrometry.

Entities:  

Year:  1998        PMID: 18967415     DOI: 10.1016/s0039-9140(98)00189-1

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Multi-instrumental Analysis of Tissues of Sunflower Plants Treated with Silver(I) Ions - Plants as Bioindicators of Environmental Pollution.

Authors:  Sona Krizkova; Pavel Ryant; Olga Krystofova; Vojtech Adam; Michaela Galiova; Miroslava Beklova; Petr Babula; Jozef Kaiser; Karel Novotny; Jan Novotny; Miroslav Liska; Radomir Malina; Josef Zehnalek; Jaromir Hubalek; Ladislav Havel; Rene Kizek
Journal:  Sensors (Basel)       Date:  2008-01-24       Impact factor: 3.576

2.  Silver(I) ions ultrasensitive detection at carbon electrodes-analysis of waters, tobacco cells and fish tissues.

Authors:  Sona Krizkova; Olga Krystofova; Libuse Trnkova; Jaromir Hubalek; Vojtech Adam; Miroslava Beklova; Ales Horna; Ladislav Havel; Rene Kizek
Journal:  Sensors (Basel)       Date:  2009-09-01       Impact factor: 3.576

3.  Determination of silver(I) by differential pulse voltammetry using a glassy carbon electrode modified with synthesized N-(2-aminoethyl)-4,4'-bipyridine.

Authors:  Maria-Cristina Radulescu; Ana Chira; Medeea Radulescu; Bogdan Bucur; Madalina Petruta Bucur; Gabriel Lucian Radu
Journal:  Sensors (Basel)       Date:  2010-12-13       Impact factor: 3.576

4.  Amperometric hydrogen peroxide biosensor based on immobilization of hemoglobin on a glassy carbon electrode modified with fe(3)o(4)/chitosan core-shell microspheres.

Authors:  Xue-Cai Tan; Jin-Lei Zhang; Sheng-Wei Tan; Dan-Dan Zhao; Zen-Wei Huang; Yan Mi; Zai-Yin Huang
Journal:  Sensors (Basel)       Date:  2009-08-05       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.