Literature DB >> 18966780

Renewable liquid film-based electrochemical sensor for gaseous hydroperoxides.

H Huang1, P K Dasgupta.   

Abstract

Electrochemical sensors for hydroperoxides based on thin flowing films were investigated. The sensor is composed of two segments of Nafion tubing put on a silver wire. A small portion of the silver wire is exposed and is chloridized to function as the reference electrode. One Nafion segment has a Pt-wire coil wrapped on it to function as the counter electrode and the other has a similar Pt-Rh wire coil that functions as the working electrode. A collection solution flows as a thin film on the sensor surface and also functions as the collection medium. Hydrogen peroxide and cumene hydroperoxide were examined as test compounds. The former can be oxidatively determined with a Pt-Rh electrode over a large range (ppb-ppm) without any significant influence of relative humidity. By using a technique to stop the liquid flow, the sensitivity can be further improved. Cumene hydroperoxide, an industrially important hydroperoxide, can be determined easily with a relative precision of better than 5% in the vapor phase over simulated process reaction mixtures containing percentage levels of the analyte by reduction on a Pd electrode. The sensor is simple and inexpensive to fabricate and requires only a suitably equipped personal computer for operation.

Entities:  

Year:  1997        PMID: 18966780     DOI: 10.1016/s0039-9140(96)02069-3

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Review of the methods for determination of reactive oxygen species and suggestion for their application in advanced oxidation induced by dielectric barrier discharges.

Authors:  Emile S Massima Mouele; Olanrewaju Ojo Fatoba; Omotola Babajide; Kassim O Badmus; Leslie F Petrik
Journal:  Environ Sci Pollut Res Int       Date:  2018-02-14       Impact factor: 4.223

2.  Detection of Hydrogen Peroxide in Liquid and Vapors Using Titanium(IV)-Based Test Strips and Low-Cost Hardware.

Authors:  Rayhan Hossain; Jimmy J Dickinson; Allen Apblett; Nicholas F Materer
Journal:  Sensors (Basel)       Date:  2022-09-02       Impact factor: 3.847

3.  Amperometric sensing of hydrogen peroxide vapor for security screening.

Authors:  John Benedet; Donglai Lu; Karel Cizek; Jeff La Belle; Joseph Wang
Journal:  Anal Bioanal Chem       Date:  2009-04-24       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.