Literature DB >> 18966565

Potentiometric flow-injection determination of trace hydrogen peroxide based on its induced reaction in iron(III)-iron(II) potential buffer containing bromide and molybdenum(VI).

H Ohura1, T Imato, S Yamasaki, N Ishibashi.   

Abstract

A rapid and highly sensitive potentiometric flow-injection method for the determination of trace hydrogen peroxide was developed by use of an Fe(III)-Fe(II) potential buffer solution containing bromide and Mo(VI). The analytical method was based on a linear relationship between a concentration of hydrogen peroxide and a largely transient potential change of an oxidation-reduction potential electrode due to bromine generated by the reaction of hydrogen peroxide with the potential buffer solution. The oxidation of bromide to bromine by hydrogen peroxide occurred very rapidly with the assistance of Mo(VI) when Fe(II) existed in the potential buffer solution. It was estimated by batchwise experiments that hydroxyl radical, OH., was generated by the reaction of hydrogen peroxide with Fe(II) as an intermediate, and subsequently oxidized bromide to bromine. In a flow system, analytical sensitivities to hydrogen peroxide obtained by the detection of the transient change of potential were enhanced about 75 fold compared with those obtained by using the potential change caused by the reaction of hydrogen peroxide with the potential buffer solution without bromide and Mo(VI). Sensitivities increased with decreasing concentration of the Fe(III)-Fe(II) buffer in the reagent solution. The detection limit (S/N = 3) of 4 x 10(-7) M (13.6 ppb) was achieved by using the 1 x 10(-4) M Fe(III)-Fe(II) buffer containing 0.4 M NaBr, 1.0 M H(2)SO(4) and 0.5% (NH(4))(6)Mo(7)O(24). Analytical throughput was approximately 40 h(-1) and the RSD (n = 6) was 0.6% for measurement of 4 x 10(-6) M hydrogen peroxide. The proposed method was applied to the determination of hydrogen peroxide in real rainwater samples, and was found to provide a good recovery for H(2)O(2) added to rainwater samples.

Entities:  

Year:  1996        PMID: 18966565     DOI: 10.1016/0039-9140(96)01840-1

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Rapid and automated analytical methods for redox species based on potentiometric flow injection analysis using potential buffers.

Authors:  Hiroki Ohura; Toshihiko Imato
Journal:  J Autom Methods Manag Chem       Date:  2011-04-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.