Literature DB >> 18965444

The use of internal standards in ICP-MS.

F Vanhaecke1, H Vanhoe, R Dams, C Vandecasteele.   

Abstract

Careful study of the matrix effect in ICP-MS showed that, in all cases studied, the magnitude of the signal suppression or enhancement depends in a regular way on the mass number. Hence, accurate correction for non-spectral interferences is only possible using an internal standard with mass number close to that of the analyte element(s). It is also shown that using an internal standard with mass number close to that of the analyte improves the precision. For both cases, the ionization energy of the internal standard seems to be of no or only secondary importance. To obtain optimal precision and accuracy, the internal standard should be selected as close in mass number as possible to that of the analyte element(s). When a number of elements over a considerable mass range are to be determined, several internal standards have to be used.

Entities:  

Year:  1992        PMID: 18965444     DOI: 10.1016/0039-9140(92)80088-u

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  8 in total

1.  A comparison of clinical laboratory data for assigning a consensus value for manganese in a caprine blood reference material.

Authors:  Meredith L Praamsma; Deanna R Jones; Jeffrey M Jarrett; Pierre Dumas; Ciprian Mihai Cirtiu; Patrick J Parsons
Journal:  J Anal At Spectrom       Date:  2012-10       Impact factor: 4.023

2.  Evidence for exposure to selenium by breeding interior snowy plovers (Charadrius nivosus) in saline systems of the Southern Great Plains.

Authors:  H M Ashbaugh; W C Conway; D A Haukos; D P Collins; C E Comer; A D French
Journal:  Ecotoxicology       Date:  2018-05-29       Impact factor: 2.823

Review 3.  Quantitative aspects of inductively coupled plasma mass spectrometry.

Authors:  Ewa Bulska; Barbara Wagner
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

Review 4.  RNAA as compared to ICP-MS for the analysis of normal human serum.

Authors:  R Dams
Journal:  Biol Trace Elem Res       Date:  1994       Impact factor: 3.738

5.  An evaluation of M2+ interference correction approaches associated with As and Se in ICP-MS using a multi-day dataset along with ICP-MS/MS/HR-ICP-MS based analysis and hierarchical modeling as a means of assessing bias in fortified drinking waters and single component matrices.

Authors:  Skyler W Smith; Roy W Martin; Nicole Hanks; Patricia A Creed; Kasey Kovalcik; Robert A Wilson; Kevin Kubachka; Judith A Brisbin; Julio A Landero Figueroa; John T Creed
Journal:  J Anal At Spectrom       Date:  2022-03-18       Impact factor: 4.351

6.  Recent advances in quantitative LA-ICP-MS analysis: challenges and solutions in the life sciences and environmental chemistry.

Authors:  Andreas Limbeck; Patrick Galler; Maximilian Bonta; Gerald Bauer; Winfried Nischkauer; Frank Vanhaecke
Journal:  Anal Bioanal Chem       Date:  2015-07-14       Impact factor: 4.142

7.  Inductively coupled plasma mass spectrometry method for plasma and intracellular antimony quantification applied to pharmacokinetics of meglumine antimoniate.

Authors:  Diana J Garay-Baquero; David E Rebellón-Sánchez; Miguel D Prieto; Lina Giraldo-Parra; Adriana Navas; Sheryl Atkinson; Stuart McDougall; Maria Adelaida Gómez
Journal:  Bioanalysis       Date:  2021-04-08       Impact factor: 2.695

Review 8.  Traditional Calibration Methods in Atomic Spectrometry and New Calibration Strategies for Inductively Coupled Plasma Mass Spectrometry.

Authors:  Jake A Carter; Ariane I Barros; Joaquim A Nóbrega; George L Donati
Journal:  Front Chem       Date:  2018-11-13       Impact factor: 5.221

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.