Literature DB >> 18965105

Enzyme electrode studies of glucose oxidase modified with a redox mediator.

P N Bartlett1, V Q Bradford, R G Whitaker.   

Abstract

Glucose oxidase modified by the covalent attachment of ferrocenecarboxylic acid or ferrocene-acetic acid groups undergoes direct oxidation at metal electrodes. Studies of the comparative stability of the two modified enzymes on storage and on electrochemical cycling show that the material modified with ferroceneacetic acid is the more stable. Amperometric studies of enzyme electrodes based on these modified forms of glucose oxidase show that their application in practical biosensors is severely limited by the poor stability of the oxidized form of the covalently attached ferrocene mediator. A comparison of the results obtained with the native enzyme and with that modified with ferroceneacetic acid, for the oxidation of glucose, d-mannose, 2-deoxy-d-glucose, d-xylose and d-galactose, suggests that the modification procedure has little effect on the selectivity of the enzyme.

Entities:  

Year:  1991        PMID: 18965105     DOI: 10.1016/0039-9140(91)80009-o

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Functionalization of Glucose Oxidase in Organic Solvent: Towards Direct Electrical Communication across Enzyme-Electrode Interface.

Authors:  Vygailė Dudkaitė; Gintautas Bagdžiūnas
Journal:  Biosensors (Basel)       Date:  2022-05-13

2.  Glucose biosensors based on dendrimer monolayers.

Authors:  M Snejdarkova; L Svobodova; V Gajdos; T Hianik
Journal:  J Mater Sci Mater Med       Date:  2001 Oct-Dec       Impact factor: 3.896

Review 3.  Enzyme Biosensors for Biomedical Applications: Strategies for Safeguarding Analytical Performances in Biological Fluids.

Authors:  Gaia Rocchitta; Angela Spanu; Sergio Babudieri; Gavinella Latte; Giordano Madeddu; Grazia Galleri; Susanna Nuvoli; Paola Bagella; Maria Ilaria Demartis; Vito Fiore; Roberto Manetti; Pier Andrea Serra
Journal:  Sensors (Basel)       Date:  2016-05-30       Impact factor: 3.576

Review 4.  Laccase and Tyrosinase Biosensors Used in the Determination of Hydroxycinnamic Acids.

Authors:  Alexandra Virginia Bounegru; Constantin Apetrei
Journal:  Int J Mol Sci       Date:  2021-05-01       Impact factor: 5.923

5.  Engineered Glucose Oxidase Capable of Quasi-Direct Electron Transfer after a Quick-and-Easy Modification with a Mediator.

Authors:  Nanami Suzuki; Jinhee Lee; Noya Loew; Yuka Takahashi-Inose; Junko Okuda-Shimazaki; Katsuhiro Kojima; Kazushige Mori; Wakako Tsugawa; Koji Sode
Journal:  Int J Mol Sci       Date:  2020-02-08       Impact factor: 5.923

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.