Literature DB >> 18964048

Polycrystalline and monocrystalline antimony, iridium and palladium as electrode material for pH-sensing electrodes.

E Kinoshita1, F Ingman, G Edwall, S Thulin, S Głab.   

Abstract

Different ways of making pH-sensing electrodes from monocrystalline or polycrystalline antimony, iridium and palladium have been investigated. Monocrystalline antimony and iridium are superior to the polycrystalline elements with respect to reproducibility between electrodes and stability of the electrode potential over long periods of time. No good palladium/palladium oxide electrode could be obtained by electrochemical oxidation and the thermal preparation method could not take advantage of the properties of the monocrystalline palladium. Therefore, only polycrystalline palladium was used to study this type of electrodes. The different electrodes were compared with respect to the manner of preparation, the pH-response (reproducibility and time response) and the effect that different complexing ligands present in the measuring solutions may have on the electrode response. Also, the redox-response of the electrodes and the effect of different oxygen pressures on the electrode potentials were studied. The monocrystalline antimony electrodes have the best reproducibility and long-term stability but also respond to complexing ligands and to variations in the oxygen pressure. Monocrystalline iridium electrodes can be obtained by continuously cycling the potential between -0.25 and +1.25 V (SCE) in 0.5M sulphuric acid. They do not respond to the complexing ligands tested, and have fairly good long-term stability, but the reproducibility between electrodes is inferior to that of the monocrystalline antimony electrodes. Polycrystalline antimony and iridium electrodes were inferior to the monocrystalline ones. The properties of the palladium electrodes were similar to those of the iridium ones.

Entities:  

Year:  1986        PMID: 18964048     DOI: 10.1016/0039-9140(86)80028-5

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A Calibration-Free pH Sensor Using an In-Situ Modified Ir Electrode for Bespoke Application in Seawater.

Authors:  Yuqi Chen; Richard Compton
Journal:  Sensors (Basel)       Date:  2022-04-25       Impact factor: 3.847

2.  Metal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook.

Authors:  Peter Kurzweil
Journal:  Sensors (Basel)       Date:  2009-06-23       Impact factor: 3.576

3.  A Multi-Parametric Device with Innovative Solid Electrodes for Long-Term Monitoring of pH, Redox-Potential and Conductivity in a Nuclear Waste Repository.

Authors:  Jordan Daoudi; Stephanie Betelu; Theodore Tzedakis; Johan Bertrand; Ioannis Ignatiadis
Journal:  Sensors (Basel)       Date:  2017-06-13       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.