Literature DB >> 18954621

Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.

C Moser1, I Opitz, W Zhai, V Rousson, E W Russi, W Weder, D Lardinois.   

Abstract

OBJECTIVE: Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial.
METHODS: Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. RESULT: Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P < .001), independently of the length of the resection. Prolonged air leak and mean duration of drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P < .001).
CONCLUSIONS: Autologous fibrin sealant for reinforcement of the staple lines after lung volume reduction surgery significantly reduces prolonged air leak and duration of chest tube drainage.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18954621     DOI: 10.1016/j.jtcvs.2008.02.079

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  16 in total

Review 1.  Several clinical interests regarding lung volume reduction surgery for severe emphysema: meta-analysis and systematic review of randomized controlled trials.

Authors:  Wei Huang; Wen R Wang; Bo Deng; You Q Tan; Guang Y Jiang; Hai Jing Zhou; Yong He
Journal:  J Cardiothorac Surg       Date:  2011-11-10       Impact factor: 1.637

Review 2.  Postoperative complications and management after lung volume reduction surgery.

Authors:  Max Lacour; Claudio Caviezel; Walter Weder; Didier Schneiter
Journal:  J Thorac Dis       Date:  2018-08       Impact factor: 2.895

Review 3.  Lung volume reduction surgery for diffuse emphysema.

Authors:  Joseph Em van Agteren; Kristin V Carson; Leong Ung Tiong; Brian J Smith
Journal:  Cochrane Database Syst Rev       Date:  2016-10-14

4.  In vivo study of novelly formulated porcine-derived fibrinogen as an efficient sealant.

Authors:  Zhang Liu; Lidong Guan; Kang Sun; Xujun Wu; Ling Su; Jifeng Hou; Miao Ye; Weihong Huang; Hongbing He
Journal:  J Mater Sci Mater Med       Date:  2015-03-07       Impact factor: 3.896

Review 5.  Elastic sealants for surgical applications.

Authors:  Nasim Annabi; Kan Yue; Ali Tamayol; Ali Khademhosseini
Journal:  Eur J Pharm Biopharm       Date:  2015-06-12       Impact factor: 5.571

6.  A prospective randomized single-blind control study of volume threshold for chest tube removal following lobectomy.

Authors:  Ye Zhang; Hui Li; Bin Hu; Tong Li; Jin-bai Miao; Bin You; Yi-li Fu; Wen-qian Zhang
Journal:  World J Surg       Date:  2014-01       Impact factor: 3.352

7.  The utility of the Stapler with PGA sheet for pulmonary wedge resection: a propensity score-matched analysis.

Authors:  Wataru Shigeeda; Hiroyuki Deguchi; Makoto Tomoyasu; Yuka Kaneko; Hironaga Kanno; Tatsuo Tanita; Hajime Saito
Journal:  J Thorac Dis       Date:  2019-04       Impact factor: 2.895

Review 8.  Lung volume reduction followed by lung transplantation-considerations on selection criteria and outcome.

Authors:  Alexis Slama; Christian Taube; Markus Kamler; Clemens Aigner
Journal:  J Thorac Dis       Date:  2018-10       Impact factor: 2.895

9.  Airtightness of lung parenchyma without a closing suture after atypical resection using the Nd:YAG Laser LIMAX 120.

Authors:  Andreas Kirschbaum; Thorsten Steinfeldt; Andreas Gockel; Pietro Di Fazio; Karl Quint; Detlef K Bartsch
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-09-30

10.  Use of staplers and adverse events in thoracic surgery.

Authors:  Dragan Subotic; Aljaz Hojski; Mark Wiese; Didier Lardinois
Journal:  J Thorac Dis       Date:  2019-05       Impact factor: 2.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.