Literature DB >> 18953251

Endoscopic ultrasound staging is adversely affected by placement of a self-expandable metal stent: fact or fiction?

Vanessa M Shami1, Anshu Mahajan, Vinay Sundaram, Eric M Davis, Michelle M Loch, Michel Kahaleh.   

Abstract

OBJECTIVES: Accurate preoperative staging of pancreatic cancer (Pca) is crucial to direct management. There is a perception that endoscopic ultrasound (EUS) staging should be performed before biliary decompression because of artifact caused by self-expandable metal stents (SEMS). Our aim is to determine whether placement of SEMS affects the staging of Pca.
METHODS: Fifty-five patients (35 men; mean age, 67 years) with newly diagnosed Pca staged in the last 5 years and captured prospectively were divided into 2 groups matched by age, sex, and final staging. The staging accuracy of EUS in patients who had a SEMS (n = 28) was compared with patients without a SEMS (n = 27). The gold standard was surgical pathology, or cytologic confirmation of metastatic disease. Multivariate analysis was effected on age, sex, presence of SEMS, and presence of metastasis to assess prediction of staging inaccuracy.
RESULTS: Endoscopic ultrasound correctly staged 14 (52%) of 27 patients in the no-SEMS group and 13 (46%) of 28 in the SEMS group. Logistic regression analysis identified only metastasis as a predictor of inaccuracy in EUS staging.
CONCLUSIONS: Endoscopic ultrasound staging of Pca does not seem to be affected by the presence of a SEMS. The major reason for misstaging in both groups was failure to detect metastatic disease.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18953251     DOI: 10.1097/MPA.0b013e3181800d2e

Source DB:  PubMed          Journal:  Pancreas        ISSN: 0885-3177            Impact factor:   3.327


  3 in total

1.  Endoscopic and anesthetic feasibility of EUS and ERCP combined in a single session versus two different sessions.

Authors:  Juan J Vila; Marcos Kutz; Silvia Goñi; Miriam Ostiz; Edurne Amorena; Carlos Prieto; Cristina Rodriguez; Ignacio Fernández-Urien; Francisco J Jiménez
Journal:  World J Gastrointest Endosc       Date:  2011-03-16

2.  Missed lesions in endoscopic ultrasound.

Authors:  Douglas G Adler; David L Diehl
Journal:  Endosc Ultrasound       Date:  2015 Jul-Sep       Impact factor: 5.628

3.  Impact of prior biliary stenting on diagnostic performance of endoscopic ultrasound for mesenteric vascular staging in patients with head of pancreas and periampullary malignancy.

Authors:  Kofi W Oppong; Manu K Nayar; Noor L H Bekkali; Pardeep Maheshwari; Beate Haugk; Antony Darne; Derek M Manas; Jeremy J French; Steven White; Gourab Sen; Sanjay Pandanaboyana; Richard M Charnley; John S Leeds
Journal:  BMJ Open Gastroenterol       Date:  2022-03
  3 in total