Literature DB >> 18952223

Kinetic plot method as a tool to design coupled column systems producing 100,000 theoretical plates in the shortest possible time.

Deirdre Cabooter1, François Lestremau, Frédéric Lynen, Pat Sandra, Gert Desmet.   

Abstract

The present paper reports on the possibility to use the kinetic plot method (KPM) to select and design the best possible system to achieve a given number (100,000) of theoretical plates for a pharmaceutical test mixture, using the information obtained from a series of single column performance measurements of sub-2microm and supra-2microm porous shell particles conducted at three different temperatures and using mixtures of acetonitrile and 0.1% formic acid in water as the mobile phase. Because the KPM involves an extrapolation to different column lengths, the quality of the design was subsequently verified by coupling several columns to achieve the optimal total column length and run the actual analysis at the calculated optimal flow rate. The prediction error was generally better than 10%, with a slightly better prediction for t(0) and N than for the retention time t(R). The sub-2microm and the porous shell particle coupled column systems achieve the 100,000 plates about equally fast, despite the fact that the former were used at 1000bar and the latter only at 600bar. The high temperature operation (80 degrees C) yielded the fastest separation in both cases, allowing to reach 100,000 plates for a component eluting at k'=2.5 in only about 15min.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18952223     DOI: 10.1016/j.chroma.2008.09.106

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

Review 1.  Quantitative mass spectrometry methods for pharmaceutical analysis.

Authors:  Glenn Loos; Ann Van Schepdael; Deirdre Cabooter
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

Review 2.  Perspectives on recent advances in the speed of high-performance liquid chromatography.

Authors:  Peter W Carr; Dwight R Stoll; Xiaoli Wang
Journal:  Anal Chem       Date:  2011-02-22       Impact factor: 6.986

3.  Graphical Method for Choosing Optimized Conditions Given a Pump Pressure and a Particle Diameter in Liquid Chromatography.

Authors:  Stephen R Groskreutz; Stephen G Weber
Journal:  Anal Chem       Date:  2016-11-16       Impact factor: 6.986

4.  Are sub-2 μm particles best for separating small molecules? An alternative.

Authors:  Joseph J DeStefano; Barry E Boyes; Stephanie A Schuster; William L Miles; Joseph J Kirkland
Journal:  J Chromatogr A       Date:  2014-10-06       Impact factor: 4.759

Review 5.  Good quantification practices of flavours and fragrances by mass spectrometry.

Authors:  Frédéric Begnaud; Alain Chaintreau
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.