Gottfried Kranz1, Dietrich Haubenberger, Bernhard Voller, Martin Posch, Peter Schnider, Eduard Auff, Thomas Sycha.
Abstract
Mouse units used to quantify the activity of botulinum A toxin preparations are not equivalent and issues concerning efficacy and safety remain with regard to their respective potencies and diffusion qualities in human tissue. We compared the effects of Botox (BOT) and Dysport (DYS) in different doses and dilutions in a human skin model. Eighteen (8 women, 10 men) healthy volunteers, aged 28.4 years +/- 5.7 years were injected intradermally with pure saline, BOT and DYS at 16 points in the abdomen in random order and in a double-blind condition, using two conversion ratios (1:3 and 1:4) and three different dilution schemes. For an objective outcome, the Ninhydrin sweat test was used to compare the anhidrotic areas. Both preparations showed a linear dose and dilution relationship with similar variances of responses for anhidrosis and hypohidrosis, indicating the same reliability of response. The dose equivalence conversion ratios (BOT: DYS) were 1:1.3 for anhidrosis and 1:1.6 for hypohidrosis (1:1.1-1.5 and 1:1.4-1.8 95% confidence intervals). The diffusion characteristics of both products were similar. A dose equivalence factor of more than 1:2 (BOT:DYS) is not supported by these objective and reproducible data.Entities:
Mesh:
Substances:
Year: 2009 PMID: 18951439 DOI: 10.1002/mds.22336
Source DB: PubMed Journal: Mov Disord ISSN: 0885-3185 Impact factor: 10.338