Literature DB >> 18950304

Optimal site for atrial lead implantation in myotonic dystrophy patients: the role of Bachmann's Bundle stimulation.

Gerardo Nigro1, Vincenzo Russo, Pasquale Vergara, Antonello D'Andrea, Grazia Di Gregorio, Luisa Politano, Giovanni Nigro, Raffaele Calabrò.   

Abstract

AIM: The aim of this study was to identify the optimal site for atrial lead implantation in myotonic dystrophy type 1 (MD1) patients.
METHODS: The atrial pacing lead was positioned in the high-lateral right atrial wall (site A), then in the right atrial appendage (site B), and finally on the interatrial septum (site C) in 22 patients. Pacing and sensing thresholds were obtained for all sites. The lead was repositioned and fixed at the optimal site, defined as the location with the lowest pacing and the highest sensing thresholds.
RESULTS: Mean pacing thresholds were 1.46 +/- 0.32 V at site A, 1.45 +/- 0.33 V at site B, and 0.84 +/- 0.24 V at site C. P-wave amplitude was 1.52 +/- 0.45 mV at site A, 1.52 +/- 0.49 mV at site B, and 2.60 +/- 0.48 mV at site C. Atrial lead was implanted at site C in all patients without complications.
CONCLUSIONS: Interatrial septum in the region of Bachmann's Bundle seems to be the optimal site for atrial lead implantation in MD1 patients.

Entities:  

Mesh:

Year:  2008        PMID: 18950304     DOI: 10.1111/j.1540-8159.2008.01210.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  14 in total

1.  Usefulness of the external loop recorder in a patient with Myotonic Dystrophy type 1 and recurrent episodes of palpitations: evaluation of the follow-up from diagnosis to 6 month-post-cardiac interventional treatment.

Authors:  Anna Rago; Andrea Antonio Papa; Dario Galante; Antonio Cassese; Paolo Golino
Journal:  Acta Myol       Date:  2018-05-01

2.  Complete resolution of left atrial appendage thrombosis with oral dabigatran etexilate in a patient with Myotonic Dystrophy type 1 and atrial fibrillation.

Authors:  Anna Rago; Andrea Antonio Papa; Giulia Arena; Marco Mosella; Antonio Cassese; Alberto Palladino; Paolo Golino
Journal:  Acta Myol       Date:  2017-12-01

3.  Is the epicardial left ventricular lead implantation an alternative approach to percutaneous attempt in patients with Steinert disease? A case report.

Authors:  Andrea Antonio Papa; Anna Rago; Roberta Petillo; Paola D'Ambrosio; Marianna Scutifero; Marisa DE Feo; Ciro Maiello; Alberto Palladino
Journal:  Acta Myol       Date:  2017-12-01

4.  Bachmann bundle pacing reduces atrial electromechanical delay in type 1 myotonic dystrophy patients.

Authors:  Vincenzo Russo; Anna Rago; Andrea Antonio Papa; Giulia Arena; Luisa Politano; Gerardo Nigro
Journal:  J Interv Card Electrophysiol       Date:  2018-02-27       Impact factor: 1.900

5.  The effect of atrial preference pacing on atrial fibrillation electrophysiological substrate in Myotonic Dystrophy type 1 population.

Authors:  Vincenzo Russo; Gerardo Nigro; Federica DI Meo; Andrea Antonio Papa; Nadia Della Cioppa; Riccardo Proietti; Maria Giovanna Russo; Raffaele Calabrò; Luisa Politano
Journal:  Acta Myol       Date:  2014-12

6.  Far field R-wave sensing in Myotonic Dystrophy type 1: right atrial appendage versus Bachmann's bundle region lead placement.

Authors:  Vincenzo Russo; Gerardo Nigro; Andrea Antonio Papa; Anna Rago; Federica Di Meo; Anna Cristiano; Antonio Molino; Raffaele Calabrò; Maria Giovanna Russo; Luisa Politano
Journal:  Acta Myol       Date:  2014-10

7.  Right atrial preference pacing algorithm in the prevention of paroxysmal atrial fibrillation in myotonic dystrophy type 1 patients: a long term follow-up study.

Authors:  Gerardo Nigro; Vincenzo Russo; Anna Rago; Andrea Antonio Papa; Alberto Palladino; Luisa Politano
Journal:  Acta Myol       Date:  2012-10

Review 8.  The heart and cardiac pacing in Steinert disease.

Authors:  Gerardo Nigro; Andrea Antonio Papa; Luisa Politano
Journal:  Acta Myol       Date:  2012-10

9.  Cardiac resynchronization improves heart failure in one patient with myotonic dystrophy type 1. A case report.

Authors:  Vincenzo Russo; Anna Rago; Andrea Antonio Papa; Gerardo Nigro
Journal:  Acta Myol       Date:  2012-10

10.  Atrial fibrillation burden in Myotonic Dystrophy type 1 patients implanted with dual chamber pacemaker: the efficacy of the overdrive atrial algorithm at 2 year follow-up.

Authors:  Vincenzo Russo; Gerardo Nigro; Anna Rago; Andrea Antonio Papa; Riccardo Proietti; Nadia Della Cioppa; Anna Cristiano; Alberto Palladino; Raffaele Calabrò; Luisa Politano
Journal:  Acta Myol       Date:  2013-12
View more