High-efficiency liquid chromatographic separation utilizing long monolithic silica capillary columns.

Kosuke Miyamoto1, Takeshi Hara, Hiroshi Kobayashi, Hironobu Morisaka, Daisuke Tokuda, Kanta Horie, Kodai Koduki, Satoshi Makino, Oscar Núñez, Chun Yang, Takefumi Kawabe, Tohru Ikegami, Hirotaka Takubo, Yasushi Ishihama, Nobuo Tanaka.   

Abstract

Long monolithic silica-C18 capillary columns of 100 microm i.d. were prepared, and the efficiency was examined using reversed-phase HPLC under a pressure of up to 47 MPa. At linear velocities of 1-2 mm/s, 100,000-500,000 theoretical plates could be generated with a single column (90-440 cm in length) using an acetonitrile-water (80/20) mobile phase with a column dead time (t0) of 5-40 min. It was possible to prepare columns with a minimum plate height of 8.5 +/- 0.5 microm and permeability of (1.45 +/- 0.09) x 10(-13) m(2). The chromatographic performance of a long octadecylsilylated monolithic silica capillary column was demonstrated by the high-efficiency separations of aromatic hydrocarbons, benzene derivatives, and a protein digest. The efficiency for a peptide was maintained for an injection of up to 0.5-2 ng. When three 100 microm i.d. columns were connected to form a 1130-1240 cm column system, 1,000,000 theoretical plates were generated for aromatic hydrocarbons with retention factors of up to 2.4 with a t0 of 150 min. The fact that very high efficiencies were obtained for the retained solutes suggests the practical utility of these long monolithic silica capillary columns.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18947204     DOI: 10.1021/ac801042c

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Arv1 promotes cell division by recruiting IQGAP1 and myosin to the cleavage furrow.

Authors:  Hilde Sundvold; Vibeke Sundvold-Gjerstad; Helle Malerød-Fjeld; Kaisa Haglund; Harald Stenmark; Lene Malerød
Journal:  Cell Cycle       Date:  2016       Impact factor: 4.534

2.  Ultra High Efficiency Protein Separations with Submicrometer Silica Using Slip Flow.

Authors:  Benjamin J Rogers; Bingchuan Wei; Mary J Wirth
Journal:  LC GC N Am       Date:  2012-10-01

3.  An Optimized Chromatographic Strategy for Multiplexing In Parallel Reaction Monitoring Mass Spectrometry: Insights from Quantitation of Activated Kinases.

Authors:  Anatoly Urisman; Rebecca S Levin; John D Gordan; James T Webber; Hilda Hernandez; Yasushi Ishihama; Kevan M Shokat; Alma L Burlingame
Journal:  Mol Cell Proteomics       Date:  2016-12-11       Impact factor: 5.911

4.  Preparation of Monolithic Capillary Chromatographic Columns Using Supercritical Fluid as a Porogen Solvent.

Authors:  Michał Szumski; Bogusław Buszewski
Journal:  Chromatographia       Date:  2014-03-16       Impact factor: 2.044

5.  Rhizobial gibberellin negatively regulates host nodule number.

Authors:  Yohei Tatsukami; Mitsuyoshi Ueda
Journal:  Sci Rep       Date:  2016-06-16       Impact factor: 4.379

6.  Metabolite profiling of the fermentation process of "yamahai-ginjo-shikomi" Japanese sake.

Authors:  Yohei Tatsukami; Hironobu Morisaka; Shunsuke Aburaya; Wataru Aoki; Chihiro Kohsaka; Masafumi Tani; Kiyoo Hirooka; Yoshihiro Yamamoto; Atsushi Kitaoka; Hisashi Fujiwara; Yoshinori Wakai; Mitsuyoshi Ueda
Journal:  PLoS One       Date:  2018-01-03       Impact factor: 3.240

7.  Proteomics tools reveal startlingly high amounts of oxytocin in plasma and serum.

Authors:  Ole Kristian Brandtzaeg; Elin Johnsen; Hanne Roberg-Larsen; Knut Fredrik Seip; Evan L MacLean; Laurence R Gesquiere; Siri Leknes; Elsa Lundanes; Steven Ray Wilson
Journal:  Sci Rep       Date:  2016-08-16       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.