Literature DB >> 18946974

Technological approaches to in-room CBCT imaging.

M F Steinke1, E Bezak.   

Abstract

The use of Cone-Beam Computed Tomography (CBCT) in Image-Guided Radiation Therapy (IGRT) has become increasingly feasible and popular in recent years. Advances and developments in Flat-Panel Imager (FPI) technology and image reconstruction software allow for linac-mounted 3D CBCT imaging. Taking CBCT images on a daily/weekly basis, offers the possibility to guide the treatment beam according to tumour motion and to apply changes to the treatment plan if necessary. This however raises the issue of additional imaging dose and thus increases in secondary cancer risk. The performance characteristics of kV-CBCT and MV-CBCT solutions currently offered by Elekta, Siemens and Varian are compared in this paper in terms of additional imaging dose and image quality. The review also outlines applications of CBCT for IGRT and Adaptive Radiotherapy (ART). As CBCT is not the only in-room IGRT platform, helical MV-CT (Tomotherapy) and in-room CT designs are also presented.

Entities:  

Mesh:

Year:  2008        PMID: 18946974     DOI: 10.1007/bf03179341

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  6 in total

1.  Evaluating the Correlation between Overjet and Skeletal Parameters Using DVT.

Authors:  Luca Lombardo; Chiara Sgarbanti; Antonio Guarneri; Giuseppe Siciliani
Journal:  Int J Dent       Date:  2012-07-31

2.  Assessment of a 2D electronic portal imaging devices-based dosimetry algorithm for pretreatment and in-vivo midplane dose verification.

Authors:  Ali Jomehzadeh; Parvaneh Shokrani; Mohammad Mohammadi; Alireza Amouheidari
Journal:  Adv Biomed Res       Date:  2016-11-28

3.  Assessing the impact of choosing different deformable registration algorithms on cone-beam CT enhancement by histogram matching.

Authors:  Halima Saadia Kidar; Hacene Azizi
Journal:  Radiat Oncol       Date:  2018-11-07       Impact factor: 3.481

Review 4.  Applications of linac-mounted kilovoltage Cone-beam Computed Tomography in modern radiation therapy: A review.

Authors:  Kavitha Srinivasan; Mohammad Mohammadi; Justin Shepherd
Journal:  Pol J Radiol       Date:  2014-07-03

5.  Improving Image Quality of On-Board Cone-Beam CT in Radiation Therapy Using Image Information Provided by Planning Multi-Detector CT: A Phantom Study.

Authors:  Ching-Ching Yang; Fong-Lin Chen; Yeh-Chi Lo
Journal:  PLoS One       Date:  2016-06-09       Impact factor: 3.240

6.  Analysis of setup error based on CTVision for nasopharyngeal carcinoma during IGRT.

Authors:  Shuxu Zhang; Xiang Zhou; Quanbin Zhang; Shaohui Jiang; Ruihao Wang; Guoqian Zhang; Huaiyu Lei; Shengqu Lin
Journal:  J Appl Clin Med Phys       Date:  2016-07-08       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.