Literature DB >> 18945610

Low potential detection of glutamate based on the electrocatalytic oxidation of NADH at thionine/single-walled carbon nanotubes composite modified electrode.

Ling Meng1, Ping Wu, Guoxiang Chen, Chenxin Cai, Yongming Sun, Zhenhong Yuan.   

Abstract

A glutamate biosensor based on the electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide (NADH), which was generated by the enzymatic reaction, was developed via employing a single-walled carbon nanotubes/thionine (Th-SWNTs) nanocomposite as a mediator and an enzyme immobilization matrix. The biosensor, which was fabricated by immobilizing glutamate dehydrogenase (GlDH) on the surface of Th-SWNTs, exhibited a rapid response (ca. 5s), a low detection limit (0.1 microM), a wide and useful linear range (0.5-400 microM), high sensitivity (137.3+/-15.7) microA mM(-1)cm(-2), higher biological affinity, as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, and 4-acetamidophenol, did not cause any interference due to the use of a low operating potential (190 mV vs. NHE). The biosensor can be used to quantify the concentration of glutamate in the physiological level. The Th-SWNTs system represents a simple and effective approach to the integration of dehydrogenase and electrodes, which can provide analytical access to a large group of enzymes for wide range of bioelectrochemical applications including biosensors and biofuel cells.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18945610     DOI: 10.1016/j.bios.2008.09.001

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  Nanomolar Detection of Glutamate at a Biosensor Based on Screen-Printed Electrodes Modified with Carbon Nanotubes.

Authors:  Raju Khan; Waldemar Gorski; Carlos D Garcia
Journal:  Electroanalysis       Date:  2011-09-20       Impact factor: 3.223

Review 2.  Advances in Medical Wearable Biosensors: Design, Fabrication and Materials Strategies in Healthcare Monitoring.

Authors:  Sangeeth Pillai; Akshaya Upadhyay; Darren Sayson; Bich Hong Nguyen; Simon D Tran
Journal:  Molecules       Date:  2021-12-28       Impact factor: 4.411

Review 3.  Latest Trends in Electrochemical Sensors for Neurotransmitters: A Review.

Authors:  Zahra Tavakolian-Ardakani; Oana Hosu; Cecilia Cristea; Mohammad Mazloum-Ardakani; Giovanna Marrazza
Journal:  Sensors (Basel)       Date:  2019-04-30       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.