Literature DB >> 18941077

Usefulness of cone-beam CT before and after percutaneous vertebroplasty.

Akio Hiwatashi1, Takashi Yoshiura, Tomoyuki Noguchi, Osamu Togao, Koji Yamashita, Hironori Kamano, Hiroshi Honda.   

Abstract

OBJECTIVE: The usefulness of cone-beam C-arm CT for percutaneous vertebroplasty has not been fully evaluated. The purpose of this study was to assess the feasibility of cone-beam CT for evaluation before and after vertebroplasty. SUBJECTS AND METHODS: This prospective study included 22 consecutive patients (15 women and seven men) with osteoporotic compression fractures (51 vertebrae). Cone-beam CT and 64-MDCT were performed before and after percutaneous vertebroplasty. Multiplanar reformations of the axial, sagittal, and coronal planes were obtained. We evaluated the presence of cortical defects, vacuum phenomena in adjacent disks, and cement leakage, and we calculated the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of cone-beam CT compared with MDCT.
RESULTS: All 75 cortical defects in 51 vertebrae seen on MDCT were also observed on cone-beam CT (100% sensitivity and specificity). Vacuum phenomena were detected in 33 of 86 (38.4%) adjacent disk spaces on MDCT and in 29 on cone-beam CT (84.8% sensitivity, 98.1% specificity, and 93.0% accuracy). Cement leakage was noted at 17 disk spaces, 15 paravertebral soft tissues, and 12 veins on MDCT. All cement leakages were correctly identified on cone-beam CT.
CONCLUSION: Cone-beam CT is able to correctly evaluate for vertebral fractures and vacuum phenomena in adjacent disks before vertebroplasty and for cement leakage after vertebroplasty.

Entities:  

Mesh:

Year:  2008        PMID: 18941077     DOI: 10.2214/AJR.08.1086

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

1.  Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT.

Authors:  Catherine M Phan; Eric A Macklin; Miriam A Bredella; Monica Dadrich; Paul Flechsig; Albert J Yoo; Joshua A Hirsch; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2010-07-25       Impact factor: 2.199

2.  Percutaneous sacroplasty with the use of C-arm flat-panel detector CT: technical feasibility and clinical outcome.

Authors:  Sung Eun Kang; Joon Woo Lee; Joo Hyung Kim; Kun Woo Park; Jin S Yeom; Heung Sik Kang
Journal:  Skeletal Radiol       Date:  2010-05-15       Impact factor: 2.199

Review 3.  [C-arm CT-guided 3D navigation of percutaneous interventions].

Authors:  H-C Becker; O Meissner; T Waggershauser
Journal:  Radiologe       Date:  2009-09       Impact factor: 0.635

4.  Percutaneous foot joint needle placement using a C-arm flat-panel detector CT.

Authors:  Martin Wiewiorski; Martin Thanh Long Takes; Victor Valderrabano; Augustinus Ludwig Jacob
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-19       Impact factor: 2.924

5.  Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography.

Authors:  Niccolò Faccioli; Giovanni Foti; Marco Barillari; Andrea Atzei; Roberto Pozzi Mucelli
Journal:  Skeletal Radiol       Date:  2010-03-12       Impact factor: 2.199

6.  Direct comparison of conventional radiography and cone-beam CT in small bone and joint trauma.

Authors:  E De Smet; G De Praeter; K L A Verstraete; K Wouters; Luc De Beuckeleer; F M H M Vanhoenacker
Journal:  Skeletal Radiol       Date:  2015-03-12       Impact factor: 2.199

7.  Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy.

Authors:  Jijo Paul; Volkmar Jacobi; Mohammad Farhang; Babak Bazrafshan; Thomas J Vogl; Emmanuel C Mbalisike
Journal:  Eur Radiol       Date:  2012-12-19       Impact factor: 5.315

8.  Novel utilization of 3D technology and the hybrid operating theatre: Peri-operative assessment of posterior sterno-clavicular dislocation using cone beam CT.

Authors:  James A Crowhurst; Douglas Campbell; Mark Whitby; Pavthrun Pathmanathan
Journal:  J Med Radiat Sci       Date:  2013-06-03
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.