| Literature DB >> 18940324 |
Lijun Zhang1, Xijun Chang, Yunhui Zhai, Qun He, Xinping Huang, Zheng Hu, Na Jiang.
Abstract
In this study, a new 4-(2-morinyldiazenyl)-N-(3-(trimethylsilyl)propyl)benzamide modified silica gel (SG-MTPB) sorbent was prepared and characterized by FT-IR spectroscopy and studied for separation and preconcentration of Sc(III) prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace Sc(III) were optimized using both batch and column procedures. At pH 3, Sc(III) could be quantitatively adsorbed on the new sorbent. And the adsorbed Sc(III) could be completely eluted by using 2 mL of 6 mol L(-1) of HCl+2% CS(NH(2))(2). Most common coexisting ions did not interfere with the separation and preconcentration of Sc(III) at optimal conditions. The maximum static adsorption capacity of the sorbent for Sc(III) was 600 micaromol g(-1) while the time of 95% adsorption was less than 2 min. The detection limit of present method was found to be 0.085 micarog g(-1), and the relative standard deviation (R.S.D.) was lower than 1.3%. The method was also successfully applied to the preconcentration of trace Sc(III) in the environmental samples with satisfactory results.Entities:
Year: 2008 PMID: 18940324 DOI: 10.1016/j.aca.2008.09.039
Source DB: PubMed Journal: Anal Chim Acta ISSN: 0003-2670 Impact factor: 6.558