Literature DB >> 18937813

Relationship between ocular pulse amplitude and systemic blood pressure measurements.

Matthias C Grieshaber1, Robert Katamay, Konstantin Gugleta, Asan Kochkorov, Josef Flammer, Selim Orgül.   

Abstract

PURPOSE: This study aimed to determine whether ocular pulse amplitude (OPA) measured with dynamic contour tonometry (DCT) is related to systemic blood pressure (BP) parameters.
METHODS: Blood pressure was measured continuously and simultaneously with OPA in one randomly selected eye in 29 healthy subjects. Systemic parameters of interest were: systolic and diastolic BPs and their difference (BP amplitude), and left ventricle ejection time (LVET; defined as the time between the diastolic trough and the incisural notch in the BP curve). In addition, the axial length (AL) of the eye was measured. Associations between OPA, AL and systemic cardiovascular parameters were analysed in a multivariate regression model.
RESULTS: Measurements of OPA ranged from 1.0 mmHg to 4.9 mmHg (mean 2.3 +/- 0.9 mmHg, median 1.9 mmHg). In a univariate analysis with one predictor at a time, means of intraocular pressure (IOP) (p = 0.008), AL (p = 0.046) and LVET (p = 0.037) were significantly correlated with OPA, whereas systolic and diastolic BPs and their amplitude were not. A multiple linear regression analysis showed that mean IOP (p < 0.005), AL (p = 0.01) and LVET (p = 0.002) all independently contributed to OPA.
CONCLUSIONS: The OPA readings measured with DCT in healthy subjects were not related to BP levels and amplitude. It seems that the OPA strongly depends on the time-course of the cardiac contraction. Regulating mechanisms in the carotid system as well as scleral rigidity may be responsible for dampening the direct effect of BP variations.

Entities:  

Mesh:

Year:  2008        PMID: 18937813     DOI: 10.1111/j.1755-3768.2008.01217.x

Source DB:  PubMed          Journal:  Acta Ophthalmol        ISSN: 1755-375X            Impact factor:   3.761


  12 in total

1.  Ocular pulse amplitude and retrobulbar blood flow change in dipper and non-dipper individuals.

Authors:  R Karadag; U C Keskin; A Koktener; Y Selcoki; I F Hepsen; M Kanbay
Journal:  Eye (Lond)       Date:  2011-03-18       Impact factor: 3.775

2.  Dynamic contour tonometry in primary open angle glaucoma and pseudoexfoliation glaucoma: factors associated with intraocular pressure and ocular pulse amplitude.

Authors:  Sasan Moghimi; Hamidreza Torabi; Ghasem Fakhraie; Nariman Nassiri; Massood Mohammadi
Journal:  Middle East Afr J Ophthalmol       Date:  2013 Apr-Jun

3.  The effect of intravitreal bevacizumab (Avastin) on ocular pulse amplitude in neovascular age-related macular degeneration.

Authors:  Ehud Rechtman; Ingeborg Stalmans; Joseph Glovinsky; Christophe Breusegem; Joseph Moisseiev; Joachim Van Calster; Alon Harris
Journal:  Clin Ophthalmol       Date:  2011-01-06

4.  Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects.

Authors:  Robert Koprowski; Lei Tian
Journal:  J Ophthalmol       Date:  2017-01-30       Impact factor: 1.909

5.  Heartbeat-Induced Corneal Axial Displacement and Strain Measured by High Frequency Ultrasound Elastography in Human Volunteers.

Authors:  Sunny Kwok; Keyton Clayson; Nicholas Hazen; Xueliang Pan; Yanhui Ma; Andrew J Hendershot; Jun Liu
Journal:  Transl Vis Sci Technol       Date:  2020-12-18       Impact factor: 3.283

6.  Measurement of Intraocular Pressure with Applanation, Dynamic Contour, and Air-Puff Tonometers: A Comparative Study in Primary Open-Angle Glaucoma and Healthy Cases.

Authors:  Kemal Turgay Özbilen; M Selim Kocabora
Journal:  Beyoglu Eye J       Date:  2020-12-28

7.  Does fundus fluorescein angiography procedure affect ocular pulse amplitude?

Authors:  Gökhan Pekel; Semra Acer; Ramazan Yagci; Ebru Nevin Cetin; Mehmet Can Hiraali; Hüseyin Kaya
Journal:  J Ophthalmol       Date:  2013-07-30       Impact factor: 1.909

8.  Clinical utility of spectral analysis of intraocular pressure pulse wave.

Authors:  Magdalena Asejczyk-Widlicka; Patrycja Krzyżanowska-Berkowska; Małgorzata Kowalska; D Robert Iskander
Journal:  BMC Ophthalmol       Date:  2014-03-12       Impact factor: 2.209

9.  Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?

Authors:  T Bertelmann; S Langanke; M Potstawa; I Strempel
Journal:  Clin Ophthalmol       Date:  2014-07-14

10.  Retinal Vessel Caliber, Choroidal Thickness and Ocular Pulse Amplitude Measurements in Essential Thrombocythemia.

Authors:  Gökhan Pekel; Mehmet Hilmi Doğu; Hakan Ismail Sarı; Semra Acer; Alper Kasikci; Ramazan Yagci; Ebru Nevin Çetin
Journal:  Middle East Afr J Ophthalmol       Date:  2016 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.