Literature DB >> 18937673

Benefits of a bolus calculator in pre- and postprandial glycaemic control and meal flexibility of paediatric patients using continuous subcutaneous insulin infusion (CSII).

B Shashaj1, E Busetto, N Sulli.   

Abstract

AIMS: To assess the efficacy in pre- and postprandial glycaemic control and the impact on treatment satisfaction of a bolus calculator (Bolus Wizard) incorporated into the insulin pump in Type 1 diabetic (T1D) paediatric patients using continuous subcutaneous insulin infusion (CSII) treatment at various stages of pubertal development.
METHODS: Thirty-six T1D patients on CSII treatment (19 males; mean age 13.9 +/- 3.5 years; range 4.9-17.8 years), were prospectively enrolled into this two-period crossover study. Eighteen patients were randomized to begin phase A using the Bolus Wizard, followed by phase B, using their current conventional insulin dosing method to determine pre-meal boluses. The remaining subjects were randomized to begin with phase B followed by phase A. Each study period lasted 2 weeks. A questionnaire assessing treatment satisfaction with the Bolus Wizard was compiled.
RESULTS: There was a significant reduction in blood glucose levels before and 2 h after meals and in the number of correction boluses during phase A with respect to phase B of the study. The lower frequency of hypoglycaemic events during phase A did not reach statistical significance. There were no differences between the two phases: insulin requirement, daily bolus rate (%) and meal bolus quantity.
CONCLUSIONS: When paediatric patients used CSII, the bolus insulin dose calculated using the Bolus Wizard was more effective in improving pre- and postprandial glycaemic control with fewer correction boluses, without differences in the prandial insulin requirements and without restriction in the carbohydrate content of meals. The use of the Bolus Wizard was easy and was associated with a high level of satisfaction in these patients.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18937673     DOI: 10.1111/j.1464-5491.2008.02549.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  24 in total

1.  Analysis of use of an automated bolus calculator reduces fear of hypoglycemia and improves confidence in dosage accuracy in type 1 diabetes mellitus patients treated with multiple daily insulin injections.

Authors:  Frank L Schwartz; Aili Guo; Cynthia R Marling; Jay H Shubrook
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

2.  Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects.

Authors:  Allen Sussman; Elizabeth J Taylor; Mona Patel; Jeanne Ward; Shridhara Alva; Andrew Lawrence; Ronald Ng
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

3.  Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects".

Authors:  Paolo Rossetti; Josep Vehí; Ana Revert; Remei Calm; Jorge Bondia
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

Review 4.  Boluses in Insulin Therapy.

Authors:  Ralph Ziegler; Guido Freckmann; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2016-07-10

5.  Bolus Calculator Safety Mandates a Need for Standards.

Authors:  John Walsh; Guido Freckmann; Ruth Roberts; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2016-12-20

Review 6.  Management of diabetes mellitus: is the pump mightier than the pen?

Authors:  John C Pickup
Journal:  Nat Rev Endocrinol       Date:  2012-02-28       Impact factor: 43.330

7.  7(th) Annual Symposium on Self-Monitoring of Blood Glucose (SMBG), May 8-10, 2014, Helsinki, Finland.

Authors:  Christopher G Parkin; Anita Mlinac; Rolf Hinzmann
Journal:  Diabetes Technol Ther       Date:  2014-09-11       Impact factor: 6.118

Review 8.  Bolus calculators.

Authors:  Signe Schmidt; Kirsten Nørgaard
Journal:  J Diabetes Sci Technol       Date:  2014-05-19

9.  Insulin pump therapy is equally effective and safe in elderly and young type 1 diabetes patients.

Authors:  Bartlomiej Matejko; Katarzyna Cyganek; Barbara Katra; Danuta Galicka-Latala; Malgorzata Grzanka; Maciej T Malecki; Tomasz Klupa
Journal:  Rev Diabet Stud       Date:  2011-08-10

10.  Glucose meters with built-in automated bolus calculator: gadget or real value for insulin-treated diabetic patients?

Authors:  Ides M Colin; Isabelle Paris
Journal:  Diabetes Ther       Date:  2012-12-19       Impact factor: 2.945

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.