BACKGROUND: The Cobra Perilaryngeal Airway (PLA) provides better sealing pressure than the Laryngeal Mask Airway Unique (LMAU) during positive-pressure ventilation in adults. We compared the performance of the CobraPLA and LMAU in infants and children.
METHODS: Two-hundred pediatric patients were randomly assigned to a CobraPLA or an Laryngeal Mask Airway (LMA). We measured airway sealing at cuff inflation pressures of 40 and 60 cm H2O; ease and time of insertion; device stability; efficacy of ventilation; number of insertion attempts; incidence of postoperative sore throat, dysphonia, laryngospasm, bronchospasm, and gastric gas insufflation. Steady-state end-tidal(CO2) was measured at the head of the CobraPLA and at the "Y-piece" piece of the anesthetic circuit. For the major outcomes, the airway groups were subdivided post hoc into small and large CobraPLA and small and large LMA subgroups. Results are presented as means +/- sds; P < 0.05 was considered statistically significant.
RESULTS: Airway sealing pressure with the cuff inflated to 60 cm H2O in the large CobraPLA subgroup (22 +/- 7 cm H2O) was significantly more than that of the small CobraPLA subgroup (18 +/- 5 cm H2O) and large LMA subgroup (16 +/- 5 cm H2O; P < 0.001). The CobraPLA was more stable than the LMA (same anatomic fit score before and after surgery) and produced less gastric insufflation. Head CobraPLA end-tidal(CO2) values were 6.4 +/- 6 mm Hg more than those of the Y piece of the circle circuit.
CONCLUSIONS: The CobraPLA airway performed as well as the LMAU during anesthesia in pediatric patients for a large range of outcomes and was superior for some.

Entities:  

Mesh:

Year:  2008        PMID: 18931209     DOI: 10.1213/ane.0b013e3181852617

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

1.  Comparison of the effects of various airway devices on hemodynamic response and QTc interval in rabbits under general anesthesia.

Authors:  Huseyin Toman; Mesut Erbas; Hasan Sahin; Hasan Ali Kiraz; Metehan Uzun; Mehmet Akif Ovali
Journal:  J Clin Monit Comput       Date:  2015-01-31       Impact factor: 2.502

2.  Comparison of Four Different Supraglottic Airway Devices in Terms of Efficacy, Intra-ocular Pressure and Haemodynamic Parameters in Children Undergoing Ophthalmic Surgery.

Authors:  Gökhan Peker; Suna Akın Takmaz; Bülent Baltacı; Hülya Başar; Mustafa Kotanoğlu
Journal:  Turk J Anaesthesiol Reanim       Date:  2015-08-21

3.  Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients.

Authors:  Karim K Girgis; Maha M I Youssef; Nashwa S ElZayyat
Journal:  Saudi J Anaesth       Date:  2014-10

4.  Cobra-PLA provides higher oropharyngeal leak pressure than LMA-Classic and LMA-Unique: A meta-analysis with 22 studies.

Authors:  Yuan Tan; Guangyou Duan; Qin Chen; Feng Chen; Hong Li
Journal:  Medicine (Baltimore)       Date:  2019-06       Impact factor: 1.817

5.  Comparison of Cobra perilaryngeal airway (CobraPLA™) with flexible laryngeal mask airway in terms of device stability and ventilation characteristics in pediatric ophthalmic surgery.

Authors:  Rani A Sunder; Renu Sinha; Anil Agarwal; Bala Chandran Sundara Perumal; Sakthi Rajan Paneerselvam
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2012-07

Review 6.  Small is the new big: An overview of newer supraglottic airways for children.

Authors:  Rakhee Goyal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Oct-Dec
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.