Literature DB >> 18930311

Accuracy of 16-row multislice computerized tomography angiography for assessment of intracranial aneurysms.

Wenhua Chen1, Jie Wang, Wei Xing, Qing Xu, Jianguo Qiu, Qingjuan Huang, Yifang Sun, Shengnan Yu, Ya Peng.   

Abstract

BACKGROUND: Sixteen-row multislice CT has great potential for use in vascular studies. The aim of the study was to assess the diagnostic accuracy of 16-row multislice CTA in detecting intracranial aneurysms compared with 2D-DSA and surgical findings.
METHODS: One hundred fifty-two consecutive patients were included in the study and successively underwent 16-slice CTA, 2D-DSA, and surgery in some patients. This was performed with a 16-row multislice CT machine, detector slice of 0.75 mm, reconstruction interval of 0.40 mm, and timing determined by bolus trigger. The 16-slice CTA and 2D-DSA results were evaluated independently by 3 different neuroradiologists who performed aneurysm detection using MIP, SSD, and VRT.
RESULTS: With the combination of 16-slice CTA, 2D-DSA, and intraoperative findings, 92 aneurysms were detected in 86 of the 152 patients. Two aneurysms were missed when 16-slice CTA was used. Three aneurysms were not clearly depicted at 2D-DSA, but proven at surgery. There was no statistically significant difference in sensitivity between 16-slice CTA and 2D-DSA (P = 1.0). The sensitivity of 16-slice CTA for detecting aneurysms <4 mm, between 4 and 10 mm, and >10 mm was 96% (95% CI: 79.6%-99.9%), 98.1% (95% CI: 89.7%-100%), and 100% (95% CI: 78.2%-100%), respectively, on a per-aneurysm basis. The sensitivity, specificity, and accuracy of 16-slice CTA for detecting aneurysms were 97.8% (95% CI: 92.4%-99.7%), 100% (95% CI: 94.6%-100%), and 98.7% (95% CI: 95.5%-99.8%), respectively, on a per-aneurysm basis.
CONCLUSION: Sixteen-slice CTA shows promising diagnostic accuracy that appears to be comparable with 2D-DSA for the detection of suspected intracranial aneurysms, and 16-slice CTA is sensitive enough to replace 2D-DSA in detecting aneurysms.

Entities:  

Mesh:

Year:  2008        PMID: 18930311     DOI: 10.1016/j.surneu.2007.08.005

Source DB:  PubMed          Journal:  Surg Neurol        ISSN: 0090-3019


  4 in total

1.  Utilization guidelines for reducing radiation exposure in the evaluation of aneurysmal subarachnoid hemorrhage: A practice quality improvement project.

Authors:  Michael L Loftus; Shlomo Minkowitz; A John Tsiouris; Robert J Min; Pina C Sanelli
Journal:  AJR Am J Roentgenol       Date:  2010-07       Impact factor: 3.959

2.  Posterior communicating artery aneurysm rupture mimicking apoplexy.

Authors:  Christopher M Bonfield; Paul A Gardner
Journal:  Surg Neurol Int       Date:  2011-11-19

3.  Applications of multislice CT angiography in the surgical clipping and endovascular coiling of intracranial aneurysms.

Authors:  Wenhua Chen; Yilin Yang; Wei Xing; Ya Peng; Jianguo Qiu; Zhongming He; Qi Wang
Journal:  J Biomed Res       Date:  2010-11

4.  Diagnostic accuracy of early computed tomographic angiography for visualizing medium sized inferior and posterior projecting carotid system aneurysms.

Authors:  Hooshang Saberi; Mohammad Hashemi; Zohreh Habibi; Ali Tayebi Meybodi; Seyed Ali Fakhr Tabatabai; Hazhir Saberi; Sofia Saboori
Journal:  Iran J Radiol       Date:  2011-11-25       Impact factor: 0.212

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.