Point of care testing: transcutaneous bilirubinometry in neonates.

A Carceller-Blanchard1, J Cousineau, E E Delvin.   

Abstract

Physicians taking care of infants in the first days of life are often faced with neonatal jaundice, especially in an era where post-partum discharge occurs earlier and assessment of newborn bilirubinemia status is required prior to discharge. The Canadian Pediatric Society and the American Academy of Pediatrics have developed and published guidelines for the diagnosis and management of hyperbilirubinemia in newborns. Point of care testing refers to any test performed outside of laboratory by clinical personnel and close to the site of patient care. Based on a summary of multiple reports during the last twenty years, we realize that devices which provide a non-invasive transcutaneous bilirubin (TcB) measurement have proven to be very useful as screening tools and provide a valid estimate of the total serum bilirubin level (TSB). Published data suggest that these devices provide measurements within 30-50 micromol/L of the TSB levels and can replace laboratory measurement particularly when TSB levels are less than 260 micromol/L. At the present time, in the literature, evidence is insufficient to abandon neonatal serum bilirubin testing and replace it with TcB. Any measurement, TSB or TcB, has potential for error. However, we have evidence that TcB, can help avoiding potential errors associated with even visual assessment of jaundice and may be useful as screening device to detect significant jaundice and decrease a large number of unnecessary skin punctures. The current manuscript is based on a careful comprehensive literature review concerning neonatal hyperbilirubinemia. We consider that this manuscript will help clinicians and laboratory professionals in the management of neonatal jaundice.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18929553     DOI: 10.1016/j.clinbiochem.2008.09.106

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  4 in total

1.  BiliCheck vs JM-103 in identifying neonates not at risk of hyperbilirubinaemia.

Authors:  Costantino Romagnoli; Piero Catenazzi; Giovanni Barone; Lucia Giordano; Riccardo Riccardi; Antonio Alberto Zuppa; Enrico Zecca
Journal:  Ital J Pediatr       Date:  2013-07-23       Impact factor: 2.638

2.  Quality improvement initiative using transcutaneous bilirubin nomogram to decrease serum bilirubin sampling in low-risk babies.

Authors:  Muhammad Hussain Shah; Shabina Ariff; Syed Rehan Ali; Rayaan Asad Chaudhry; Maryam Pyar Ali Lakhdir; Fatima Qaiser; Simon Demas; Ali Shabbir Hussain
Journal:  BMJ Paediatr Open       Date:  2019-04-24

3.  Improving quality of transcutaneous bilirubin measurements: Value of in-house developed quality control.

Authors:  Heather Anne Paul; Brenda Joanne Adams; Allison Anne Venner
Journal:  Pract Lab Med       Date:  2021-01-28

4.  Effectiveness of transcutaneous bilirubin measurement in managing neonatal jaundice in postnatal ward of a tertiary care hospital in Pakistan.

Authors:  Ali Shabbir Hussain; Muhammad Hussain Shah; Maryam Lakhdir; Shabina Ariff; Simon Demas; Fatima Qaiser; Syed Rehan Ali
Journal:  BMJ Paediatr Open       Date:  2017-08-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.