Literature DB >> 18928485

Noninvasive control of adequate cerebral oxygenation during low-flow antegrade selective cerebral perfusion on adults and infants in the aortic arch surgery.

Alvaro Rubio1, Lale Hakami, Frank Münch, René Tandler, Frank Harig, Michael Weyand.   

Abstract

UNLABELLED: Real-time readings of the regional oxygen saturation (rSO(2)) using near-infrared spectroscopy (NIRS) during the aortic arch surgery can provide an early detection of perfusion or oxygenation abnormalities.
BACKGROUND: Aortic arch repair techniques using low-flow antegrade selective cerebral perfusion have been standardized to a certain degree. However, some of the often-stated beneficial effects have never been proven. Especially, the existence of an adequate continuous flow in both cerebral hemispheres during the surgical procedure still remains unclear as the monitoring of an effective perfusion remains a nonstandardized technique.
METHODS: Seventeen patients underwent surgical reconstruction of the aortic arch due to aortic aneurysm surgery (adult group n = 8 patients) or of the hypoplastic aortic arch due to hypoplastic left heart syndrome (HLHS) or aortic coarctation (infant group n = 9 patients) under general anesthesia and mild hypothermia (adult group 28 degrees C; infant group 25 degrees C). Mean weights were 92.75 +/- 14.00 kg and 4.29 +/- 1.32 kg, and mean ages were 58.25 +/- 10.19 years and 55.67 +/- 51.11 days in the adult group and the infant group, respectively. The cerebral O(2) saturation measurement was performed by continuous plotting of the somatic reflectance oximetry of the frontal regional tissue on both cerebral hemispheres (rSO(2), INVOS; Somanetics Corporation, Troy, MI, USA).
RESULTS: During low-flow antegrade perfusion via innominate artery, continuous plots with similar values of O(2) saturation (rSO(2)) in both cerebral hemispheres were observed, whereas a decrease in the rSO(2) values below the desaturation threshold correlated with a displacement or an incorrect positioning of the arterial cannula in the right subclavian artery.
CONCLUSIONS: Continuous monitorization of the cerebral O(2) saturation during aortic arch surgery in adults and infants is a feasible technique to control an adequate cannula positioning and to optimize clinical outcomes avoiding neurological complications related to cerebral malperfusion.

Entities:  

Mesh:

Year:  2008        PMID: 18928485     DOI: 10.1111/j.1540-8191.2008.00644.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  10 in total

1.  Technical description of the use of selective perfusion techniques during the Norwood procedure for hypoplastic left heart syndrome.

Authors:  David Leonard Chabot; Anastasios C Polimenakos
Journal:  J Extra Corpor Technol       Date:  2011-12

Review 2.  [Type A dissection. Principles of anesthesiological management].

Authors:  J Roggenbach; H Rauch
Journal:  Anaesthesist       Date:  2011-02       Impact factor: 1.041

3.  Continuous-wave near-infrared spectroscopy is not related to brain tissue oxygen tension.

Authors:  Thomas Kerz; Christian Beyer; Alexandra Huthmann; Darius Kalasauskas; Amr Nimer Amr; Stephan Boor; Stefan Welschehold
Journal:  J Clin Monit Comput       Date:  2015-08-20       Impact factor: 2.502

Review 4.  Cerebral Oximetry and Autoregulation during Cardiopulmonary Bypass: A Review.

Authors:  Nousjka P A Vranken; Patrick W Weerwind; Nadia A Sutedja; Ervin E Ševerdija; Paul J C Barenbrug; Jos G Maessen
Journal:  J Extra Corpor Technol       Date:  2017-09

Review 5.  Cerebral and tissue oximetry.

Authors:  Jochen Steppan; Charles W Hogue
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2014-09-28

Review 6.  Cerebral near-infrared spectroscopy monitoring and neurologic outcomes in adult cardiac surgery patients: a systematic review.

Authors:  Fei Zheng; Rosanne Sheinberg; May-Sann Yee; Masa Ono; Yueyging Zheng; Charles W Hogue
Journal:  Anesth Analg       Date:  2012-12-24       Impact factor: 5.108

7.  Hippocampal cellular loss after brief hypotension.

Authors:  Rafael E Chaparro; Carolina Quiroga; Gerardo Bosco; Diana Erasso; Alessandro Rubini; Devanand Mangar; Andrea Parmagnani; Enrico M Camporesi
Journal:  Springerplus       Date:  2013-01-25

8.  Impact of bispectral index monitoring on postoperative delirium in patients undergoing aortic surgery.

Authors:  G Santarpino; R Fasol; J Sirch; B Ackermann; S Pfeiffer; T Fischlein
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2011

9.  Current conduct of deep hypothermic circulatory arrest in China.

Authors:  J G T Augoustides; P Patel; K Ghadimi; J Choi; Y Yue; G Silvay
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2013

10.  Continuous measurement of cerebral oxygenation with near-infrared spectroscopy after spontaneous subarachnoid hemorrhage.

Authors:  Homajoun Maslehaty; Ulf Krause-Titz; Athanassios K Petridis; Harald Barth; Hubertus Maximilian Mehdorn
Journal:  ISRN Neurol       Date:  2012-11-14