Literature DB >> 18924102

A continuous wavelet transform algorithm for peak detection.

Andrew Wee1, David B Grayden, Yonggang Zhu, Karolina Petkovic-Duran, David Smith.   

Abstract

Contactless conductivity detector technology has unique advantages for microfluidic applications. However, the low S/N and varying baseline makes the signal analysis difficult. In this paper, a continuous wavelet transform-based peak detection algorithm was developed for CE signals from microfluidic chips. The Ridger peak detection algorithm is based on the MassSpecWavelet algorithm by Du et al. [Bioinformatics 2006, 22, 2059-2065], and performs a continuous wavelet transform on data, using a wavelet proportional to the first derivative of a Gaussian function. It forms sequences of local maxima and minima in the continuous wavelet transform, before pairing sequences of maxima to minima to define peaks. The peak detection algorithm was tested against the Cromwell, MassSpecWavelet, and Linear Matrix-assisted laser desorption/ionization-time-of-flight-mass spectrometer Peak Indication and Classification algorithms using experimental data. Its sensitivity to false discovery rate curve is superior to other techniques tested.

Mesh:

Year:  2008        PMID: 18924102     DOI: 10.1002/elps.200800096

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  5 in total

1.  FDR control of detected regions by multiscale matched filtering.

Authors:  Nezamoddin N Kachouie; Xihong Lin; Armin Schwartzman
Journal:  Commun Stat Simul Comput       Date:  2014-12-23       Impact factor: 1.118

2.  Spectral Wavelet-feature Analysis and Classification Assisted Denoising for enhancing magnetic resonance spectroscopy.

Authors:  Bing Ji; Zahra Hosseini; Liya Wang; Lei Zhou; Xinhua Tu; Hui Mao
Journal:  NMR Biomed       Date:  2021-03-09       Impact factor: 4.044

3.  Design Rationale and Performance Evaluation of the Wavelet Health Wristband: Benchtop Validation of a Wrist-Worn Physiological Signal Recorder.

Authors:  Onur Dur; Reinier van Mourik; Colleen Rhoades; Man Suen Ng; Ragwa Elsayed; Maulik D Majmudar
Journal:  JMIR Mhealth Uhealth       Date:  2018-10-16       Impact factor: 4.773

4.  Automatic no-reference image quality assessment.

Authors:  Hongjun Li; Wei Hu; Zi-Neng Xu
Journal:  Springerplus       Date:  2016-07-16

5.  A Pilot Study for Estimating the Cardiopulmonary Signals of Diverse Exotic Animals Using a Digital Camera.

Authors:  Ali Al-Naji; Yiting Tao; Ian Smith; Javaan Chahl
Journal:  Sensors (Basel)       Date:  2019-12-10       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.