Literature DB >> 18923815

The results of cataract nigra cases operated with the mini-nuc technique.

Erdal Yuzbasioglu1, Firat Helvacioglu, Betul Tugcu, Nazire Terzi, Kadircan Keskinbora.   

Abstract

The purpose of this study was to evaluate the efficacy and safety of the mini-nuc technique for the removal of brunescent and black cataracts. A prospective study was carried out in 33 eyes of 33 patients with cataract nigra operated with the mini-nuc technique between April 2002 and June 2003. Slit-lamp examinations, intraocular pressure (IOP) measurements, and best-corrected visual acuity (BCVA) were assessed pre- and postoperatively. Accompanying systemic diseases were noted. Intraoperative and postoperative complications were evaluated. Unilateral eyes of 33 patients (18 male [54.5%], 15 female [45.5%]) aged between 65 and 90 years (mean 72 years) were operated with the mini-nuc technique. Preoperative BCVA values varied between light perception and 0.2 in the Snellen chart. Intraocular lenses (IOL) were implanted into all of the patients (27 in-the-bag [81.8%], four to sulcus [12.1%], and two with scleral fixation [6.1%]). During the surgery, five patients (15.15%) had zonular dialysis and two (6.1%) had posterior capsule rupture and vitreous loss. Postoperatively, three (9.1%) rises in IOP, two (6.1%) hyphema, and one (3%) IOL subluxation were observed. At the first day visit, the mean of the uncorrected visual acuities (UCVA) was 0.5 in the Snellen chart. At the third month visit, the mean BCVA was observed to be 0.8. The residual mean astigmatism was 0.75 D against the rule. The mini-nuc technique was effective in removing brunescent and black cataracts with a low rate of serious complications. The mini-nuc technique, which is also performed with a small incision and without sutures, might be an alternative to phacoemulsification in cases of cataract nigra.

Entities:  

Mesh:

Year:  2008        PMID: 18923815     DOI: 10.1007/s10792-008-9265-8

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  19 in total

1.  Mini-nuc technique in phacoemulsification.

Authors:  Kadircan H Keskinbora
Journal:  J Cataract Refract Surg       Date:  2004-11       Impact factor: 3.351

2.  Mini-nuc technique.

Authors:  Vikas Chadha; Basudeb Ghosh; Ashish Lall
Journal:  J Cataract Refract Surg       Date:  2005-12       Impact factor: 3.351

3.  Phacoemulsification learning curve: experience of two junior trainee ophthalmologists.

Authors:  S Prasad
Journal:  J Cataract Refract Surg       Date:  1998-01       Impact factor: 3.351

4.  Manual ECCE, the present state of the art.

Authors:  M Blumenthal
Journal:  Klin Monbl Augenheilkd       Date:  1994-11       Impact factor: 0.700

5.  Stop and chop phacoemulsification.

Authors:  P S Koch; L E Katzen
Journal:  J Cataract Refract Surg       Date:  1994-09       Impact factor: 3.351

6.  Extracapsular cataract extraction to phacoemulsification: why and how?

Authors:  B Gonglore; R Smith
Journal:  Eye (Lond)       Date:  1998       Impact factor: 3.775

7.  Phacoemulsification of brunescent and black cataracts.

Authors:  R Singh; A R Vasavada; G Janaswamy
Journal:  J Cataract Refract Surg       Date:  2001-11       Impact factor: 3.351

8.  Blindness and low vision in southeast Turkey.

Authors:  A D Negrel; D C Minassian; F Sayek
Journal:  Ophthalmic Epidemiol       Date:  1996-12       Impact factor: 1.648

9.  Prevalence of cataract and pseudophakia/aphakia among adults in the United States.

Authors:  Nathan Congdon; Johannes R Vingerling; Barbara E K Klein; Sheila West; David S Friedman; John Kempen; Benita O'Colmain; Suh-Yuh Wu; Hugh R Taylor
Journal:  Arch Ophthalmol       Date:  2004-04

10.  Effect of cataract surgery on the corneal endothelium: modern phacoemulsification compared with extracapsular cataract surgery.

Authors:  Rupert R A Bourne; Darwin C Minassian; John K G Dart; Paul Rosen; Sundeep Kaushal; Nicholas Wingate
Journal:  Ophthalmology       Date:  2004-04       Impact factor: 12.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.