Literature DB >> 1892292

Effects of positive end-expiratory pressure, lung volume, and inspiratory flow on interrupter resistance in patients with adult respiratory distress syndrome.

N T Eissa1, V M Ranieri, C Corbeil, M Chassé, J Braidy, J Milic-Emili.   

Abstract

Although it has been shown in normal subjects that airway resistance changes significantly with changes in lung volume and inspiratory flow, no studies have as yet examined these phenomena in patients with adult respiratory distress syndrome (ARDS). The effect of positive end-expiratory pressure (PEEP) on airway resistance in ARDS also is unknown. We have used the technique of rapid airway occlusion during constant-flow inflation to measure the interrupter resistance (Rint,rs), which in humans is thought to correspond to airway resistance, in nine patients with ARDS under different inflation flows and volumes. This procedure was carried out at four levels of PEEP (0, 5, 10, and 15 cm H2O). We found that (1) at constant inflation volume, Rint,rs did not change significantly with increasing flow; (2) at constant inflation flow, Rint,rs showed an initial decrease followed by a distinct rise with increasing lung volume; (3) on average, PEEP did not significantly change Rint,rs measured during baseline ventilation; and (4) this latter finding occurred because patients behaved differently with application of PEEP, depending on their degree of lung inflation: Rint,rs measured close to full inflation almost invariably exhibited a rise, but values obtained at lower volumes exhibited the characteristic decrease of Rint,rs with increasing inflation volume.

Entities:  

Mesh:

Year:  1991        PMID: 1892292     DOI: 10.1164/ajrccm/144.3_Pt_1.538

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  4 in total

1.  Evaluation of respiratory system resistance in mechanically ventilated patients: the role of the endotracheal tube.

Authors:  G Conti; R A De Blasi; A Lappa; A Ferretti; M Antonelli; M Bufi; A Gasparetto
Journal:  Intensive Care Med       Date:  1994-07       Impact factor: 17.440

2.  Effect of tidal volume and positive end-expiratory pressure on expiratory time constants in experimental lung injury.

Authors:  William R Henderson; Paolo B Dominelli; Yannick Molgat-Seon; Rachel Lipson; Donald E G Griesdale; Mypinder Sekhon; Najib Ayas; A William Sheel
Journal:  Physiol Rep       Date:  2016-03

3.  Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.

Authors:  Savino Spadaro; Tommaso Mauri; Stephan H Böhm; Gaetano Scaramuzzo; Cecilia Turrini; Andreas D Waldmann; Riccardo Ragazzi; Antonio Pesenti; Carlo Alberto Volta
Journal:  Crit Care       Date:  2018-01-31       Impact factor: 9.097

Review 4.  Airway Closure and Expiratory Flow Limitation in Acute Respiratory Distress Syndrome.

Authors:  Claude Guérin; Martin Cour; Laurent Argaud
Journal:  Front Physiol       Date:  2022-01-17       Impact factor: 4.566

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.