Quantification of sleep disordered breathing by computerized analysis of oximetry, heart rate and snoring.

H Rauscher1, W Popp, H Zwick.   

Abstract

Intermittent snoring and cyclic oscillations of heart rate and oxyhaemoglobin saturation (Sao2) are characteristic features of the obstructive sleep apnoea syndrome (OSAS). Thus, overnight recordings of laryngeal sounds and heart rate by a portable device (MESAM) and of Sao2 by oximetry are applicable to screen outpatients for the presence of OSAS. Computerized analysis for time intervals of constant heart rate and intervals between snoring sounds is used by MESAM to quantify respiratory disturbances during sleep. Rapid increases in Sao2 during the postapnoeic hyperventilation period together with the number of desaturations are used by a new software for quantitative analysis of oximetry. To elucidate reliability of results from automatically scored MESAM and oximetry recordings, we compared the four computer calculated respiratory disturbance indices from heart rate (RDIH), snoring (RDIS), resaturations (RDIR) and desaturations (RDID) with the apnoea plus hypopnoea index (AHI) from simultaneously performed polysomnography. The study population consisted of 53 snorers with an AHI of 19.0 +/- 2.6 (median +/- SEM; range 0.7-87.8). Whereas both RDI's from MESAM correlated rather weakly with the AHI from polysomnography (RDIH: r = 0.32, p less than 0.05; RDIS: r = 0.33, p less than 0.05), this correlation was much better for the RDI's from oximetry (RDIR: r = 0.951, RDID: r = 0.93; p much less than 0.0001). Accepting a plus/minus 30 percent difference from the AHI, the RDIR classified 77% of patients correctly, the RDID 62%, the RDIS 32% and the RDIH 23%. In conclusion, results from computerized analysis of oximetry for desaturations and rapid resaturations correlate more closely with polysomnography than those from automatic scoring of MESAM recordings.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1889491

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  4 in total

1.  Computer-Assisted Automated Scoring of Polysomnograms Using the Somnolyzer System.

Authors:  Naresh M Punjabi; Naima Shifa; Georg Dorffner; Susheel Patil; Grace Pien; Rashmi N Aurora
Journal:  Sleep       Date:  2015-10-01       Impact factor: 5.849

2.  Identification of sleep disruption and sleep disordered breathing from the systolic blood pressure profile.

Authors:  R J Davies; K Vardi-Visy; M Clarke; J R Stradling
Journal:  Thorax       Date:  1993-12       Impact factor: 9.139

3.  First results of a prospective study validating the method of ambulatory polysomnography using the POLY-MESAM unit.

Authors:  T Verse; B Junge-Hülsing; B Kroker; W Pirsig; E Zimmermann
Journal:  Sleep Breath       Date:  1997-06       Impact factor: 2.816

4.  Automatic detection of whole night snoring events using non-contact microphone.

Authors:  Eliran Dafna; Ariel Tarasiuk; Yaniv Zigel
Journal:  PLoS One       Date:  2013-12-31       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.