| Literature DB >> 1886439 |
R A Weatherly1, J J Owens, F I Catlin, D H Mahoney.
Abstract
Despite the recognized ototoxicity of cis-platinum, a clinical outline for the audiologic evaluation of patients receiving this drug has not been clearly defined. In a practical approach to this problem, the audiograms of 48 pediatric patients referred for monitoring during planned cis-platinum therapy were reviewed. Eleven patients tested with auditory brain-stem response (ABR) audiometry demonstrated several limitations of this modality. Fourteen children underwent initial ABR testing followed by at least two pure-tone audiograms. The remaining 23 patients had their hearing evaluated by pure-tone audiometry only. Various factors such as patient age, cis-platinum dosage, and cranial radiation exposure were analyzed for apparent effect. Younger patients tended to be more susceptible to audiologic changes with the administration of cis-platinum. The proportion of patients who demonstrated a hearing loss increased with successive dosing as did the severity of the hearing loss. Prior exposure to cranial radiation was strongly linked to the development of hearing loss following cis-platinum therapy. Guidelines are presented regarding the use of clinical audiometry in the screening of these pediatric oncology patients.Entities:
Mesh:
Substances:
Year: 1991 PMID: 1886439 DOI: 10.1288/00005537-199109000-00001
Source DB: PubMed Journal: Laryngoscope ISSN: 0023-852X Impact factor: 3.325