Literature DB >> 1885970

Determination of cerebrospinal fluid shunt obstruction with magnetic resonance phase imaging.

J M Drake1, A J Martin, R M Henkleman.   

Abstract

The cerebrospinal fluid (CSF) flow rates in 12 patients with symptoms suggestive of CSF shunt obstruction were measured with magnetic resonance (MR) phase imaging. The shunts were imaged over the skull, just distal to any reservoir, using a curved surface coil. Images perpendicular to the direction of flow were made on a 1.5-tesla clinical unit with a flow-sensitive pulse sequence. The patients' ages ranged from 2 months to 28 years. All patients had ancillary investigations to determine the functional status of the shunt. No flow was detected in seven patients with blocked shunts. Flow rates between 3 and 40 cc/hr were found in three patients with functioning shunts. Two patients, one with a blocked shunt and one with a functioning shunt, could not be imaged due to motion artifact. Magnetic resonance phase imaging is a promising technique in the determination of CSF shunt obstruction.

Entities:  

Mesh:

Year:  1991        PMID: 1885970     DOI: 10.3171/jns.1991.75.4.0535

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  6 in total

1.  The adult radiographic shuntogram.

Authors:  W S Bartynski; S Valliappan; J H Uselman; M P Spearman
Journal:  AJNR Am J Neuroradiol       Date:  2000-04       Impact factor: 3.825

2.  Magnetic resonance imaging flow void changes after cerebrospinal fluid shunt in post-traumatic hydrocephalus: clinical correlations and outcome.

Authors:  Paolo Missori; Massimo Miscusi; Rita Formisano; Simone Peschillo; Filippo M Polli; Antonio Melone; Stefano Martini; Sergio Paolini; Roberto Delfini
Journal:  Neurosurg Rev       Date:  2006-05-31       Impact factor: 3.042

3.  Cerebrospinal fluid flow and production in patients with normal pressure hydrocephalus studied by MRI.

Authors:  P Gideon; F Ståhlberg; C Thomsen; F Gjerris; P S Sørensen; O Henriksen
Journal:  Neuroradiology       Date:  1994-04       Impact factor: 2.804

4.  Quantitative contrast-enhanced ultrasound measurement of cerebrospinal fluid flow for the diagnosis of ventricular shunt malfunction.

Authors:  Robin Hartman; Salavat Aglyamov; Douglas J Fox; Stanislav Emelianov
Journal:  J Neurosurg       Date:  2015-06-19       Impact factor: 5.115

5.  Laparoscopic management of distal ventriculoperitoneal shunt complications.

Authors:  V Nfonsam; B Chand; S Rosenblatt; R Turner; M Luciano
Journal:  Surg Endosc       Date:  2008-01-03       Impact factor: 4.584

6.  Complications with shunts in adults with spina bifida.

Authors:  P Tomlinson; I D Sugarman
Journal:  BMJ       Date:  1995-07-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.