Three-dimensional volumetric display of CT data: effect of scan parameters upon image quality.

D R Ney1, E K Fishman, D Magid, D D Robertson, A Kawashima.   

Abstract

Of the many steps involved in producing high quality three-dimensional (3D) images of CT data, the data acquisition step is of greatest consequence. The principle of "garbage in, garbage out" applies to 3D imaging--bad scanning technique produces equally bad 3D images. We present a formal study of the effect of two basic scanning parameters, slice thickness and slice spacing, on image quality. Three standard test objects were studied using variable CT scanning parameters. The objects chosen were a bone phantom, a cadaver femur with a simulated 5 mm fracture gap, and a cadaver femur with a simulated 1 mm fracture gap. Each object was scanned at three collimations: 8, 4, and 2 mm. For each collimation, four sets of scans were performed using four slice intervals: 8, 4, 3, and 2 mm. The bone phantom was scanned in two positions: oriented perpendicular to the scanning plane and oriented 45 degrees from the scanning plane. Three-dimensional images of the resulting 48 sets of data were produced using volumetric rendering. Blind review of the resultant 48 data sets was performed by three reviewers rating five factors for each image. The images resulting from scans with thin collimation and small table increments proved to rate the highest in all areas. The data obtained using 2 mm slice intervals proved to rate the highest in perceived image quality. Three millimeter slice spacing with 4 mm collimation, which clinically provides a good compromise between image quality and acquisition time and dose, also produced good perceived image quality. The studies with 8 mm slice intervals provided the least detail and introduced the worst inaccuracies and artifacts and were not suitable for clinical use. Statistical analysis demonstrated that slice interval (i.e., table incrementation) was of primary importance and slice collimation was of secondary, although significant, importance in determining perceived 3D image quality.

Entities:  

Mesh:

Year:  1991        PMID: 1885819     DOI: 10.1097/00004728-199109000-00033

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  6 in total

1.  Multi-detector row CT scanning in Paleoanthropology at various tube current settings and scanning mode.

Authors:  J Badawi-Fayad; C Yazbeck; A Balzeau; T H Nguyen; A Istoc; D Grimaud-Hervé; E- A Cabanis
Journal:  Surg Radiol Anat       Date:  2005-10-07       Impact factor: 1.246

2.  Assessment of real-time 3D visualization for cardiothoracic diagnostic evaluation and surgery planning.

Authors:  Bradley M Hemminger; Paul L Molina; Thomas M Egan; Frank C Detterbeck; Keith E Muller; Christopher S Coffey; Joseph K T Lee
Journal:  J Digit Imaging       Date:  2005-06       Impact factor: 4.056

3.  Real-time stereographic rendering and display of medical images with programmable GPUs.

Authors:  Xiao Hui Wang; Walter F Good
Journal:  Comput Med Imaging Graph       Date:  2007-12-03       Impact factor: 4.790

4.  Development of a simulation system in mandibular orthognathic surgery based on integrated three-dimensional data.

Authors:  Yoshihide Mori; Hidetaka Shimizu; Katsuhiro Minami; Tae-Geon Kwon; Takamitsu Mano
Journal:  Oral Maxillofac Surg       Date:  2010-10-28

5.  Comparison of 2D and 3D digital subtraction angiography in evaluation of intracranial aneurysms.

Authors:  Takeshi Sugahara; Yukunori Korogi; Kouji Nakashima; Satoshi Hamatake; Shin Honda; Mutsumasa Takahashi
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

6.  The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters.

Authors:  Ji Hoon Shin; Ho Kyu Lee; Choong Gon Choi; Dae Chul Suh; Tae Hwan Lim; Weechang Kang
Journal:  Korean J Radiol       Date:  2002 Jan-Mar       Impact factor: 3.500

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.