Literature DB >> 18854989

Development of a univariate calibration model for pharmaceutical analysis based on NIR spectra.

M Blanco1, J Cruz, M Bautista.   

Abstract

Near-infrared spectroscopy (NIRS) has been widely used in the pharmaceutical field because of its ability to provide quality information about drugs in near-real time. In practice, however, the NIRS technique requires construction of multivariate models in order to correct collinearity and the typically poor selectivity of NIR spectra. In this work, a new methodology for constructing simple NIR calibration models has been developed, based on the spectrum for the target analyte (usually the active principle ingredient, API), which is compared with that of the sample in order to calculate a correlation coefficient. To this end, calibration samples are prepared spanning an adequate concentration range for the API and their spectra are recorded. The model thus obtained by relating the correlation coefficient to the sample concentration is subjected to least-squares regression. The API concentration in validation samples is predicted by interpolating their correlation coefficients in the straight calibration line previously obtained. The proposed method affords quantitation of API in pharmaceuticals undergoing physical changes during their production process (e.g. granulates, and coated and non-coated tablets). The results obtained with the proposed methodology, based on correlation coefficients, were compared with the predictions of PLS1 calibration models, with which a different model is required for each type of sample. Error values lower than 1-2% were obtained in the analysis of three types of sample using the same model; these errors are similar to those obtained by applying three PLS models for granules, and non-coated and coated samples. Based on the outcome, our methodology is a straightforward choice for constructing calibration models affording expeditious prediction of new samples with varying physical properties. This makes it an effective alternative to multivariate calibration, which requires use of a different model for each type of sample, depending on its physical presentation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18854989     DOI: 10.1007/s00216-008-2426-9

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Micro-Raman spectroscopy and univariate analysis for monitoring disease follow-up.

Authors:  Carlo Camerlingo; Ines Delfino; Giuseppe Perna; Vito Capozzi; Maria Lepore
Journal:  Sensors (Basel)       Date:  2011-08-25       Impact factor: 3.576

2.  Evaluation of some non-invasive approaches for the detection of red palm weevil infestation.

Authors:  Khawaja Ghulam Rasool; Mureed Husain; Shehzad Salman; Muhammad Tufail; Sukirno Sukirno; Khalid Mehmood; Wazirzada Aslam Farooq; Abdulrahman S Aldawood
Journal:  Saudi J Biol Sci       Date:  2019-10-30       Impact factor: 4.219

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.