Literature DB >> 18854738

Intermediate-term outcome and success of superior versus inferior Ahmed Glaucoma Valve implantation.

Rony Rachmiel1, Graham E Trope, Yvonne M Buys, John G Flanagan, Mary L Chipman.   

Abstract

PURPOSE: The superotemporal quadrant is usually the implantation site of choice for glaucoma drainage devices. Inferior placement of glaucoma drainage device is considered technically difficult. The purpose was to determine the success rates, complications, and visual outcome of superior versus inferior Ahmed Glaucoma Valve implantation. PATIENTS AND METHODS: A retrospective review of the records of 83 eyes (77 patients) that underwent Ahmed Glaucoma Valve surgery from 1997 to 2004. Thirty-one eyes had superior insertion (SI) versus 52 eyes with inferior insertion (II). Demographic, preoperative, and postoperative data including intraocular pressure (IOP), visual acuity, and number of medications, and complications were recorded. Success was defined as postoperative IOP between 5 and 21 mm Hg and at least a 20% reduction from baseline IOP.
RESULTS: The mean postoperative IOPs at 6 months, 1, 2, 2.5, and 3 years were 13.5+/-3.2 mm Hg versus 12.8+/-3.6 mm Hg (P=0.76), 12.5+/-3.1 mm Hg versus 13.0+/-4.0 mm Hg (P=0.5), 15.7+/-6.2 mm Hg versus 12.6+/-4.7 mm Hg (P=0.06), 13.2+/-3.0 mm Hg versus 12.6+/-3.3 mm Hg (P=0.70), and 14.5+/-3.0 mm Hg versus 13.7+/-5.0 mm Hg (P=0.73) in the SI group versus the II group, respectively. The success rates were similar between the groups over the study period with 87.0% versus 86.5%, 71.5% versus 73.0%, and 71.5% versus 64.6% for SI versus II at 12, 24, and 36 months, respectively. There were more complications in the II group; however, only wound dehiscence and transient diplopia were statistically significant (P=0.04 and 0.001, respectively). The number of glaucoma medications was lower in the SI during the first 3 months but nonsignificant thereafter.
CONCLUSIONS: There was no significant difference in IOP control between SI and II over 36 months. II should be considered when there are limitations to SI.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18854738     DOI: 10.1097/IJG.0b013e31816299bc

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  10 in total

1.  Glaucoma drainage devices: risk of exposure and infection.

Authors:  Joshua D Levinson; Annette L Giangiacomo; Allen D Beck; Paul B Pruett; Hillary M Superak; Michael J Lynn; Anastasios P Costarides
Journal:  Am J Ophthalmol       Date:  2015-05-30       Impact factor: 5.258

Review 2.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

3.  The Ahmed glaucoma valve in neovascular glaucoma (An AOS Thesis).

Authors:  Peter A Netland
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

4.  Surgical outcomes of superior versus inferior glaucoma drainage device implantation.

Authors:  Amy Z Martino; Shawn Iverson; William J Feuer; David S Greenfield
Journal:  J Glaucoma       Date:  2015-01       Impact factor: 2.503

5.  Analysis of Schwalbe's Line (Limbal Smooth Zone) by Scanning Electron Microscopy and Optical Coherence Tomography in Human Eye Bank Eyes.

Authors:  Mark P Breazzano; Michael Fikhman; Jerrold L Abraham; Ann E Barker-Griffith
Journal:  J Ophthalmic Vis Res       Date:  2013-01

6.  Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

Authors:  Oriel Spierer; Michael Waisbourd; Yitzhak Golan; Hadas Newman; Rony Rachmiel
Journal:  BMC Ophthalmol       Date:  2016-02-27       Impact factor: 2.209

7.  Quantification of the Posterior Cornea Using Swept Source Optical Coherence Tomography.

Authors:  Stephen Wahlig; Gary Hin-Fai Yam; Wesley Chong; Xin-Yi Seah; Viridiana Kocaba; Marcus Ang; Hla Myint Htoon; Tin A Tun; Hon Shing Ong; Jodhbir S Mehta
Journal:  Transl Vis Sci Technol       Date:  2018-09-04       Impact factor: 3.283

8.  Partial thickness cornea tissue from small incision lenticule extraction: A novel patch graft in glaucoma drainage implant surgery.

Authors:  Yuhong Wang; Xiaofeng Li; Weiyi Huang; Jinkun Liu; Yazhang Xu; Meizhu Chen; Qian Wang
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

9.  Outcomes of XEN Gel Stent Implantation in the Inferonasal Quadrant after Failed Trabeculectomy.

Authors:  Eyüp Düzgün; Ali Olgun; Murat Karapapak; Abdurrahman Alpaslan Alkan; Melih Ustaoğlu
Journal:  J Curr Glaucoma Pract       Date:  2021 May-Aug

10.  Hypertensive phase and early complications after Ahmed glaucoma valve implantation with intraoperative subtenon triamcinolone acetonide.

Authors:  Angela V Turalba; Louis R Pasquale
Journal:  Clin Ophthalmol       Date:  2014-07-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.