Epigastric electrical impedance for the quantitative determination of the gastric acidity.

A C Giouvanoudi1, N M Spyrou.   

Abstract

Electrical impedance measurements have been used by scientists since the 1980s to investigate the gastric function. In this work, these measurements were carried out using the epigastrograph, a device generating alternating current of 32 kHz and injecting it in the gastric area of the human body with surface electrodes, located around the abdominal area. Although the method has been used for about three decades the physiological interpretation of these measurements is still under research. This work states that the electrical impedance measurements from the gastric area depend on the conductivity of the gastric lumen, due mainly to gastric acid secretions and to the conductivity and chemical form of the ingested meal. By choosing the proper test meal the gastric acidity in the empty, healthy stomach was also estimated. The estimated value is in accordance with the literature. The method is non-invasive, relatively inexpensive, simple to medical technologists and subjects, and involves no radiation risk. The method may form the basis for the development of a non-invasive gastric pH meter.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18854603     DOI: 10.1088/0967-3334/29/11/006

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  4 in total

1.  Gastric motility functional study based on electrical bioimpedance measurements and simultaneous electrogastrography.

Authors:  Zhang-Yong Li; Chao-Shi Ren; Shu Zhao; Hong Sha; Juan Deng
Journal:  J Zhejiang Univ Sci B       Date:  2011-12       Impact factor: 3.066

2.  Electrical bioimpedance gastric motility measurement based on an electrical-mechanical composite mechanism.

Authors:  Shu Zhao; Hong Sha; Zhang-Yong Li; Chao-Shi Ren
Journal:  World J Gastroenterol       Date:  2012-07-07       Impact factor: 5.742

3.  Effects of metoclopramide on gastric motility measured by short-term bio-impedance.

Authors:  María-Raquel Huerta-Franco; Miguel Vargas-Luna; Kathleen M Capaccione; Etna Yañez-Roldán; Ulises Hernández-Ledezma; Ismael Morales-Mata; Teodoro Córdova-Fraga
Journal:  World J Gastroenterol       Date:  2009-10-14       Impact factor: 5.742

4.  Electrical bioimpedance and other techniques for gastric emptying and motility evaluation.

Authors:  María Raquel Huerta-Franco; Miguel Vargas-Luna; Juana Berenice Montes-Frausto; Corina Flores-Hernández; Ismael Morales-Mata
Journal:  World J Gastrointest Pathophysiol       Date:  2012-02-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.