Literature DB >> 18853587

Dreaming and recall during sedation for colonoscopy.

M L Stait1, K Leslie, R Bailey.   

Abstract

Dreaming is reported by one in five patients who are interviewed on emergence from general anaesthesia, but the incidence, predictors and consequences of dreaming during procedural sedation are not known. In this prospective observational study, 200 patients presenting for elective colonoscopy under intravenous sedation were interviewed on emergence to determine the incidences of dreaming and recall. Sedation technique was left to the discretion of the anaesthetist. The incidence of dreaming was 25.5%. Patients reporting dreaming were younger than those who did not report dreaming. Doses of midazolam and fentanyl were similar between dreamers and non-dreamers, however propofol doses were higher in patients who reported dreams than those who did not. Patients reported short, simple dreams about everyday life--no dream suggested near-miss recall of the procedure. Frank recall of the procedure was reported by 4% of the patients, which was consistent with propofol doses commensurate with light general anaesthesia. The only significant predictor of recall was lower propofol dose. Satisfaction with care was generally high, however dreamers were more satisfied with their care than non-dreamers.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18853587     DOI: 10.1177/0310057X0803600509

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  5 in total

1.  Feasibility of measuring memory response to increasing dexmedetomidine sedation in children.

Authors:  K P Mason; E R Kelhoffer; R Prescilla; M Mehta; J C Root; V J Young; F Robinson; R A Veselis
Journal:  Br J Anaesth       Date:  2017-02       Impact factor: 9.166

2.  Identifying Recall Under Sedation by a Novel EEG Based Index of Attention-A Pilot Study.

Authors:  Dana Baron Shahaf; Avi Weissman; Leonid Priven; Goded Shahaf
Journal:  Front Med (Lausanne)       Date:  2022-04-14

3.  Bispectral Index Monitoring and Observer Rating Scale Correlate with Dreaming during Propofol Anesthesia for Gastrointestinal Endoscopies.

Authors:  Helena Matus; Slavica Kvolik; Andreja Rakipovic; Vladimir Borzan
Journal:  Medicina (Kaunas)       Date:  2021-12-31       Impact factor: 2.430

4.  The Impact of Endoscopy Sedation Information Sheets on the Level of Concern Regarding Possible Awareness in Patients Undergoing Endoscopy Sedation.

Authors:  Zi Ping Tong; Lincoln Gan Lim; Alison Pighills; Matthew Hiskens; Danny Bartlett
Journal:  Healthcare (Basel)       Date:  2021-12-24

5.  Anesthetic dreaming, anesthesia awareness and patient satisfaction after deep sedation with propofol target controlled infusion: A prospective cohort study of patients undergoing day case breast surgery.

Authors:  Marco Cascella; Roberta Fusco; Domenico Caliendo; Vincenza Granata; Domenico Carbone; Maria Rosaria Muzio; Giuseppe Laurelli; Stefano Greggi; Francesca Falcone; Cira Antonietta Forte; Arturo Cuomo
Journal:  Oncotarget       Date:  2017-04-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.