Literature DB >> 18850551

Intermediate visual acuity without spectacles following bilateral ReSTOR implantation.

C Cuq1, C Spera, C Laurendeau, A Lafuma, G Berdeaux.   

Abstract

PURPOSE: This survey determined uncorrected visual acuity (VA) at near, intermediate, and far distances in cataract patients implanted with ReSTOR, and assessed patient satisfaction.
METHODS: Consecutive cataract patients implanted bilaterally with ReSTOR were followed up at least 4 months. The Early Treatment Diabetic Retinopathy Study scale was used to measure VA for near (40 cm), intermediate (50, 60, and 70 cm), and distance vision, with VAs expressed in logMAR and adjusted for distance using Bennett's (1993) formula. Satisfaction was self-rated on a visual analogue scale ranging from 0 (poor) to 10 (high).
RESULTS: Twenty-four consecutive patients (mean age 67.6 years) were operated upon by a single surgeon and followed up for a mean of 336.5 days after second eye surgery. Average postoperative VAs for uncorrected distance were 0.06 logMAR and intermediate VAs were 0.21 logMAR at both 50 cm and 60 cm and 0.22 logMAR at 70 cm. These levels of uncorrected intermediate VA would allow patients to read Word computer text in Times New Roman font 8 zoomed to 100%, at 70 cm from the monitor screen. The authors found that23/24 patients (96%) no longer wore spectacles. The remaining patient required correction for astigmatism as this refraction error is not yet correctable by ReSTOR. Average selfrated satisfaction was 8.54.
CONCLUSIONS: In an everyday surgical practice, none of the studied bilateral ReSTOR cataract patients without astigmatism required spectacles when followed up 6 months or later. Intermediate VA was compatible with reading and led to high patient satisfaction.

Entities:  

Mesh:

Year:  2008        PMID: 18850551     DOI: 10.1177/112067210801800512

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  3 in total

1.  Spectacle independence and subjective satisfaction of ReSTOR multifocal intraocular lens after cataract or presbyopia surgery in two European countries.

Authors:  Béatrice Cochener; Luis Fernández-Vega; Jose F Alfonso; Frédérique Maurel; Juliette Meunier; Gilles Berdeaux
Journal:  Clin Ophthalmol       Date:  2010-03-04

2.  Visual outcomes and patient satisfaction after refractive lens exchange with a single-piece diffractive multifocal intraocular lens.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2014-11-23       Impact factor: 1.909

3.  Visual Outcomes, Quality of Vision, and Quality of Life of Diffractive Multifocal Intraocular Lens Implantation after Myopic Laser In Situ Keratomileusis: A Prospective, Observational Case Series.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2017-01-04       Impact factor: 1.909

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.