Literature DB >> 18849130

Focal liver lesion detection and characterization: comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging.

Kenneth Coenegrachts1, Celso Matos, Léon ter Beek, Thierry Metens, Marc Haspeslagh, Shandra Bipat, Jaap Stoker, Hans Rigauts.   

Abstract

PURPOSE: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs).
MATERIALS AND METHODS: Twenty-five patients suspected for colorectal liver metastases were prospectively included. Lesion detection and characterization were compared between all SS SE-EPI and T2-weighted turbo spin echo (T2w TSE) sets (two-sided Fisher's exact test). Image quality and lesion conspicuity were compared for SS SE-EPI sets using rank order statistic (RIDIT). Reference standard comprised of surgery, biopsy and/or follow-up.
RESULTS: Reference standard demonstrated 18 benign and 43 malignant FLLs. Best lesion detection (p<0.05) was achieved with non-contrast-enhanced SS SE-EPI. Lesion characterization was best using all T2w TSE sequences. Best image quality and lesion conspicuity (p<0.05) was achieved with non-contrast-enhanced SS SE-EPI.
CONCLUSION: Non-contrast-enhanced SS SE-EPI was best for lesion detection. SS SE-EPI sequences were not useful for lesion characterization (differentiation between benign and malignant lesions). Unenhanced SS SE-EPI did not allow differentiation especially as many benign FLLs were hyperintense on the highest b-value images. Combining unenhanced and SPIO-enhanced SS SE-EPI performed better but still was not clinically useful due to variable degree of uptake and vascular pooling of SPIO for (especially) benign FLLs. T2w TSE with SPIO-enhancement was needed for characterization.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18849130     DOI: 10.1016/j.ejrad.2008.09.005

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  8 in total

Review 1.  Diffusion weighted imaging in the liver.

Authors:  Petra G Kele; Eric J van der Jagt
Journal:  World J Gastroenterol       Date:  2010-04-07       Impact factor: 5.742

2.  Characterization of focal liver lesions using quantitative techniques: comparison of apparent diffusion coefficient values and T2 relaxation times.

Authors:  Andrzej Cieszanowski; Agnieszka Anysz-Grodzicka; Wojciech Szeszkowski; Bartosz Kaczynski; Edyta Maj; Barbara Gornicka; Mariusz Grodzicki; Ireneusz P Grudzinski; Anna Stadnik; Marek Krawczyk; Olgierd Rowinski
Journal:  Eur Radiol       Date:  2012-06-15       Impact factor: 5.315

3.  Gadoxetate-enhanced versus diffusion-weighted MRI for fused Ga-68-DOTANOC PET/MRI in patients with neuroendocrine tumours of the upper abdomen.

Authors:  Marius E Mayerhoefer; Ahmed Ba-Ssalamah; Michael Weber; Markus Mitterhauser; Harald Eidherr; Wolfgang Wadsak; Markus Raderer; Siegfried Trattnig; Andreas Herneth; Georgios Karanikas
Journal:  Eur Radiol       Date:  2013-03-08       Impact factor: 5.315

4.  A meta-analysis of diffusion-weighted and gadoxetic acid-enhanced MR imaging for the detection of liver metastases.

Authors:  Valérie Vilgrain; Maxime Esvan; Maxime Ronot; Aurore Caumont-Prim; Christophe Aubé; Gilles Chatellier
Journal:  Eur Radiol       Date:  2016-02-16       Impact factor: 5.315

5.  Multifunctional Chitosan Magnetic-Graphene (CMG) Nanoparticles: a Theranostic Platform for Tumor-targeted Co-delivery of Drugs, Genes and MRI Contrast Agents.

Authors:  Chunyan Wang; Sowndharya Ravi; Ujjwala Sree Garapati; Mahasweta Das; Mark Howell; Jaya MallelaMallela; Subbiah Alwarapan; Shyam S Mohapatra; Subhra Mohapatra
Journal:  J Mater Chem B       Date:  2013-09-21       Impact factor: 6.331

6.  Diffusion-weighted MR imaging before and after contrast enhancement with superparamagnetic iron oxide for assessment of hepatic metastasis.

Authors:  Hana Kim; Jeong-Sik Yu; Dae Jung Kim; Jae-Joon Chung; Joo Hee Kim; Ki Whang Kim
Journal:  Yonsei Med J       Date:  2012-07-01       Impact factor: 2.759

7.  Quantification of hepatic iron concentration in chronic viral hepatitis: usefulness of T2-weighted single-shot spin-echo echo-planar MR imaging.

Authors:  Tatsuyuki Tonan; Kiminori Fujimoto; Aliya Qayyum; Takumi Kawaguchi; Atsushi Kawaguchi; Osamu Nakashima; Koji Okuda; Naofumi Hayabuchi; Michio Sata
Journal:  PLoS One       Date:  2012-03-16       Impact factor: 3.240

Review 8.  Diffusion-weighted imaging of the liver: an update.

Authors:  N Bharwani; D M Koh
Journal:  Cancer Imaging       Date:  2013-04-15       Impact factor: 3.909

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.