Literature DB >> 18849069

Evaluation of poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) conduits for peripheral nerve regeneration.

Yu-Zhu Bian1, Yang Wang, G Aibaidoula, Guo-Qiang Chen, Qiong Wu.   

Abstract

Poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) (PHBHHx) was investigated for possible application in repairing damaged nerves. Porous nerve conduits with both uniform wall porosity and non-uniform wall porosity were prepared using a particle leaching method. Adult Sprague-Dawley (SD) rats weighing 200-250 g were used as the animal model. The conduits were employed to bridge the 10mm defects in the sciatic nerve of the Sprague-Dawley (SD) rats. Mechanical tests showed that the PHBHHx nerve conduits had proper mechanical properties including maximal loads of 3.1N and 1.3N for the conduits with non-uniform wall porosity and with uniform wall porosity, respectively, and maximal stresses of 2.3 MPa and 0.94 MPa for the conduits with non-uniform wall porosity and with uniform wall porosity, respectively. At the same time, both types of conduits were permeable to three compounds tested including glucose, lysozyme and bovine serum albumin, indicating the suitability of the conduits for free exchanges of nutrients. Compound Muscle Action Potentials (CMAPs) were clearly observed in both types of the PHBHHx nerve conduits after 1 month of implantation, indicating a rapid functional recovery for the disrupted nerves. The results of histological sections demonstrated that the internal sides of the conduits with non-uniform wall porosity were compact enough to prevent the connective tissues from ingrowth penetration. After implantation for 3 months in the rats, the conduits with uniform wall porosity and those with non-uniform wall porosity lost 24% and 20% of their original weight average molecular weights, respectively. Combined with the strong mechanical properties, good nerve regeneration ability and non-toxicity of its degradation products, PHBHHx nerve conduits can be developed into a useful material to repair nerve damage.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18849069     DOI: 10.1016/j.biomaterials.2008.09.036

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  23 in total

1.  Biosynthesis and characterization of a novel, biocompatible medium chain length polyhydroxyalkanoate by Pseudomonas mendocina CH50 using coconut oil as the carbon source.

Authors:  Pooja Basnett; Elena Marcello; Barbara Lukasiewicz; Bijal Panchal; Rinat Nigmatullin; Jonathan C Knowles; Ipsita Roy
Journal:  J Mater Sci Mater Med       Date:  2018-11-30       Impact factor: 3.896

2.  In vivo application of poly-3-hydroxyoctanoate as peripheral nerve graft.

Authors:  D Burcu Hazer; Ercan Bal; Gülay Nurlu; Kemal Benli; Serdar Balci; Feral Öztürk; Baki Hazer
Journal:  J Zhejiang Univ Sci B       Date:  2013-11       Impact factor: 3.066

3.  Evaluation of PHBHHx and PHBV/PLA fibers used as medical sutures.

Authors:  Yu He; Zhiwei Hu; Mengda Ren; Changkun Ding; Peng Chen; Qun Gu; Qiong Wu
Journal:  J Mater Sci Mater Med       Date:  2013-11-01       Impact factor: 3.896

4.  The development of a normalization method for comparing nerve regeneration effectiveness among different graft types.

Authors:  Wei Chang; Jeffrey DeVince; Gabriella Green; Munish Bhupendra Shah; Michael S Johns; Yan Meng; Xiaojun Yu
Journal:  J Peripher Nerv Syst       Date:  2013-12       Impact factor: 3.494

Review 5.  Biomedical Applications of Polyhydroxyalkanoates.

Authors:  Subhasree Ray; Vipin Chandra Kalia
Journal:  Indian J Microbiol       Date:  2017-04-22       Impact factor: 2.461

6.  Electroactive polymers for tissue regeneration: Developments and perspectives.

Authors:  Chengyun Ning; Zhengnan Zhou; Guoxin Tan; Ye Zhu; Chuanbin Mao
Journal:  Prog Polym Sci       Date:  2018-05-07       Impact factor: 29.190

7.  Biofabrication and testing of a fully cellular nerve graft.

Authors:  Christopher M Owens; Francoise Marga; Gabor Forgacs; Cheryl M Heesch
Journal:  Biofabrication       Date:  2013-11-06       Impact factor: 9.954

8.  Poly (3-hydroxybutyrate-co-3-hydroxyhexanoate)/collagen hybrid scaffolds for tissue engineering applications.

Authors:  Alex J Lomas; William R Webb; JianFeng Han; Guo-Qiang Chen; Xun Sun; Zhirong Zhang; Alicia J El Haj; Nicholas R Forsyth
Journal:  Tissue Eng Part C Methods       Date:  2013-02-14       Impact factor: 3.056

9.  A comparison of the performance of mono- and bi-component electrospun conduits in a rat sciatic model.

Authors:  Valentina Cirillo; Basak A Clements; Vincenzo Guarino; Jared Bushman; Joachim Kohn; Luigi Ambrosio
Journal:  Biomaterials       Date:  2014-07-29       Impact factor: 12.479

10.  Preparation and evaluation of novel nano-bioglass/gelatin conduit for peripheral nerve regeneration.

Authors:  Masoumeh Foroutan Koudehi; Abbas Ali Imani Fooladi; Kourosh Mansoori; Zahra Jamalpoor; Afsaneh Amiri; Mohammad Reza Nourani
Journal:  J Mater Sci Mater Med       Date:  2013-11-02       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.