Evaluation of a new laser surface implant: scanning electron microscopy/energy dispersive X-ray and X-ray photoelectron spectroscopy analyses.

D Berardi1, M Colagiovanni, A Scoccia, L Raffaelli, P F Manicone, G Perfetti.   

Abstract

The roughness and the purity of implant surfaces are key points in the osteointegration process. The surfaces obtained by classic methods present irregular non-reproducible patterns and furthermore contaminate the implant surface with materials other than titanium which interfere with the process of osteointegration. The aim of the present study is to evaluate, by SEM/EDX and XPS analyses, the surface microstructure and the purity of new laser-treated implant surfaces. The laser treatment of the surface allows to set parameters to determine the roughness in order to obtain a regular and repeatable surface. Furthermore, there being no contact between the implant and the machine, there is no surface contamination with elements other than titanium. In this study we used a diode-pumped solid state laser (DPSS) with Nd:YAG source operating in Q-Switching mode on titanium samples. The resulting samples were analysed by SEM/EDX and XPS to evaluate morphology and purity of the surface. The results show surfaces with very regular roughness and a total absence of contamination.

Entities:  

Mesh:

Year:  2008        PMID: 18842169

Source DB:  PubMed          Journal:  J Biol Regul Homeost Agents        ISSN: 0393-974X            Impact factor:   1.711


  3 in total

1.  Radiographic bone level around particular laser-treated dental implants: 1 to 6 years multicenter retrospective study.

Authors:  C Mongardini; B Zeza; P Pelagalli; R Blasone; M Scilla; M Berardini
Journal:  Int J Implant Dent       Date:  2020-07-28

2.  Laser microtextured titanium implant surfaces reduce in vitro and in situ oral biofilm formation.

Authors:  Andrei C Ionescu; Eugenio Brambilla; Francesco Azzola; Marco Ottobelli; Gaia Pellegrini; Luca A Francetti
Journal:  PLoS One       Date:  2018-09-07       Impact factor: 3.240

3.  Gingival Response to Dental Implant: Comparison Study on the Effects of New Nanopored Laser-Treated vs. Traditional Healing Abutments.

Authors:  Barbara Ghinassi; Angela Di Baldassarre; Gianmaria D'Addazio; Tonino Traini; Mauro Andrisani; Giorgio Di Vincenzo; Giulia Gaggi; Maurizio Piattelli; Sergio Caputi; Bruna Sinjari
Journal:  Int J Mol Sci       Date:  2020-08-22       Impact factor: 5.923