Literature DB >> 18842109

Troponin revisited 2008: assay performance.

Jillian R Tate1.   

Abstract

Troponin quality specifications describing the pre-analytical, analytical and post-analytical performance of cardiac troponin (cTn) assays are important for both manufacturers of cTn assays and laboratories that routinely test for cTn. Pre-analytical requirements refer not only to acceptable sample type for analysis and the stability of cTn but also to the proper handling of specimens prior to analysis to avoid pre-analytical false positive results. Analytical issues that may contribute to differences between cTn assays include analytical sensitivity and imprecision at low cTn concentration, antibody specificity and immunoreactivity of plasma cTn forms, assay specificity and the presence of falsely positive and negative interferences, and for cTnI the lack of standardised measurement, all which may impact on patient cTn results. Current second generation cTnI and fourth generation cTnT assays generally have an imprecision of around 20% coefficient of variation (CV) at the 99th percentile of the reference population, which is greater than the recommended imprecision of 10% CV. As the next generation of more analytically sensitive cTn assays are developed it can be anticipated that cTn upper reference limits will decrease by approximately 10-fold. Monitoring assay imprecision at ultra low cTn concentrations will require that the laboratory uses a quality control close to this level and a negative control to monitor baseline drift. Establishment of cTn reference ranges will require reference populations to be cardio-healthy to enable differentiation from community populations who are at increased cardiovascular risk. Close collaboration between the laboratory and local clinicians is required to ensure adequate clinical validation of more sensitive cTn assays.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18842109     DOI: 10.1515/CCLM.2008.292

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  11 in total

1.  High-sensitivity cardiac troponin T and cognitive function and dementia risk: the atherosclerosis risk in communities study.

Authors:  Andrea L C Schneider; Andreea M Rawlings; A Richey Sharrett; Alvaro Alonso; Thomas H Mosley; Ron C Hoogeveen; Christie M Ballantyne; Rebecca F Gottesman; Elizabeth Selvin
Journal:  Eur Heart J       Date:  2014-03-30       Impact factor: 29.983

2.  Multiple immunoassay systems are negatively interfered by circulating cardiac troponin I autoantibodies.

Authors:  Gusheng Tang; Yu Wu; Weiguo Zhao; Qian Shen
Journal:  Clin Exp Med       Date:  2011-06-08       Impact factor: 3.984

3.  Performance of the high-sensitivity troponin assay in diagnosing acute myocardial infarction: systematic review and meta-analysis.

Authors:  Ayman Al-Saleh; Ashraf Alazzoni; Saleh Al Shalash; Chenglin Ye; Lawrence Mbuagbaw; Lehana Thabane; Sanjit S Jolly
Journal:  CMAJ Open       Date:  2014-07-22

Review 4.  The utility of troponin measurement to detect myocardial infarction: review of the current findings.

Authors:  Melissa A Daubert; Allen Jeremias
Journal:  Vasc Health Risk Manag       Date:  2010-09-07

5.  Alcohol Consumption and Cardiac Biomarkers: The Atherosclerosis Risk in Communities (ARIC) Study.

Authors:  Mariana Lazo; Yuan Chen; John W McEvoy; Chiadi Ndumele; Suma Konety; Christie M Ballantyne; A Richey Sharrett; Elizabeth Selvin
Journal:  Clin Chem       Date:  2016-07-20       Impact factor: 8.327

6.  Interference-free photoelectrochemical immunoassays using carboxymethylated dextran-coated and gold-modified TiO2 nanotube arrays.

Authors:  Wanze Guo; Jinping Wang; Wenjuan Guo; Qing Kang; Feimeng Zhou
Journal:  Anal Bioanal Chem       Date:  2021-06-11       Impact factor: 4.142

7.  Cardiogoniometry as a diagnostic tool in patients with acute coronary syndromes: results of the CGM@ACS trial.

Authors:  Ralph Tölg; Uwe Zeymer; Ralf Birkemeyer; Rainer Wessely; Holger Eggebrecht; Wolfgang Bocksch; Steffen Schneider; Gert Richardt; Christian Hamm
Journal:  Clin Res Cardiol       Date:  2012-04-07       Impact factor: 5.460

8.  Combined determination of highly sensitive troponin T and copeptin for early exclusion of acute myocardial infarction: first experience in an emergency department of a general hospital.

Authors:  Ulrich Lotze; Holger Lemm; Anke Heyer; Karin Müller
Journal:  Vasc Health Risk Manag       Date:  2011-08-19

9.  Long-Range Surface Plasmon-Polariton Waveguide Biosensors for Human Cardiac Troponin I Detection.

Authors:  Oleksiy Krupin; Pierre Berini
Journal:  Sensors (Basel)       Date:  2019-02-02       Impact factor: 3.576

10.  The importance of having a flexible scope ISO 15189 accreditation and quality specifications based on biological variation--the case of validation of the biochemistry analyzer Dimension Vista.

Authors:  Pilar Fernandez-Calle; Sandra Pelaz; Paloma Oliver; Maria Jose Alcaide; Ruben Gomez-Rioja; Antonio Buno; Jose Manuel Iturzaeta
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.