Literature DB >> 18841499

Development of magnetic particle-based chemiluminescence enzyme immunoassay for the detection of 17beta-estradiol in environmental water.

Tian-Bing Xin1, Xu Wang, Hui Jin, Shu-Xuan Liang, Jin-Ming Lin, Zhen-Jia Li.   

Abstract

In the present work, a simple, fast, and highly sensitive chemiluminescence enzyme immunoassay for 17beta-estradiol (E2) in environmental water samples was developed, using magnetic particles (MPs) labeled with secondary antibody as both the immobilization matrix and the separation tools. The specific anti-E2 polyclonal antibody (PcAb) was produced against a conjugate of estradiol-bovine serum albumin. The specificity of the anti-E2 antibody was studied. The results showed that the antibody did not cross-react with the structurally related endocrine-disrupting compounds, including estrone, ethinyl E2, estriol, E2-17-glucuronide, E2-3-sulfate-17-glucuronide, androstenedione, and dihydrotestosterone. The water samples were pretreated with solid-phase extraction using C18 cartridges for the removal of matrix effects. Several physicochemical parameters including the dilution ratios of E2-6-horseradish peroxidase conjugate and anti-E2 PcAb, immunoreaction time, volume of chemiluminescent substrate and MPs, chemiluminescence reaction time, and pH of assay solution were studied and optimized. At optimal experimental conditions, it was found that the proposed method exhibited high performance with detection limit of 2.0 pg/mL, linear range of 20-1,200 pg/mL, and total assay time of 45 min. Both inter- and intra-assay coefficient of variation were less than 10%. The average recoveries of three different spiked concentration samples ranged from 86.3% to 108%. The method was successfully applied to the determination of E2 in river, waste, and tap water, and showed a good correlation with the commercially available radioimmunoassay kit.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18841499     DOI: 10.1007/s12010-008-8356-3

Source DB:  PubMed          Journal:  Appl Biochem Biotechnol        ISSN: 0273-2289            Impact factor:   2.926


  2 in total

Review 1.  Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses.

Authors:  Parvez Khan; Danish Idrees; Michael A Moxley; John A Corbett; Faizan Ahmad; Guido von Figura; William S Sly; Abdul Waheed; Md Imtaiyaz Hassan
Journal:  Appl Biochem Biotechnol       Date:  2014-04-22       Impact factor: 2.926

2.  A rapid magnetic bead-based immunoassay for sensitive determination of diclofenac.

Authors:  Alexander Ecke; Tanja Westphalen; Jane Hornung; Michael Voetz; Rudolf J Schneider
Journal:  Anal Bioanal Chem       Date:  2021-11-20       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.